Short form report, Long form report, Long-form report page #1 – Agilent Technologies EN 61000-3-2 User Manual

Page 60

Advertising
background image

5 - Viewing Test Data

60

Long Form Report

The long form report presents all of the information as the short-form report but also includes all of the
final test data, which appears on subsequent pages of the report.

The following is a sample long form report

of a Fluctuating Current Harmonics test:

Long-Form Report page #1

IEC 1000-3-2/EN 61000-3-2 Fluctuating Current Harmonics Test
Date Performed: 05/10/96

Test Executed By: A.C. Testright
Company Name: True Test Laboratories
Device Under Test ID: Model 12345 Modular Power Supply
Test ID: 00123

Approved by: QA
Signature:________________________________________________________ Date:__________________

Final Test Result: FAIL

Settings and Test Conditions Compliant to the Standard: Yes

Test Equipment Used:

Agilent 6842A Harmonic/Flicker Test System with serial number 3440A-00101

Agilent 14761A HFTS software Version: A.00.05

Date Last Calibrated: June 6, 1997

Test Equipment Settings:
------------------------
Line Voltage: 230.00 V

Current Measurement Range: High

Line Frequency: 50 Hz

Measurement Window Type: Rectangular

Device Class: D

Measurement Delay: 10.0 seconds

RMS Current Limit: 13.1 A

Fluctuating Test Duration: 2.00 minutes

Peak Current Limit: 80.8 A

Class Determination Pre-test Duration: 10.00 seconds

Number of Records: 375

Overrides:
----------
Test Limit Source (Power Measurements/Statistics): Maximum
Power Overrides: None
Test Limit Overrides: None

Pre-test Results for Class Determination:
-----------------------------------------
Percent in Envelope: 100.0%

Voltage THD Out-of-Specification?: No

Class D Equipment?: Yes

Fundamental Current: 1.343 A

RMS Voltage: 229.8 V

RMS Current: 1.7 A

Real Power: 148.8 W

Frequency: 50.0 Hz

Peak Current: 5.2 A

Apparent Power: 384.2 VA

Voltage THD: 0.10%

Current THD: 80.68%

Power Factor: 0.387

Maximum Power: 148.8 W

Mean Power: 146.7 W

Active Power Statistics:
------------------------
100th percentile: 148.8 W

99th Percentile: 147.3 W

95th Percentile: 147.3 W

90th Percentile: 147.3 W

50th Percentile: 146.2 W

Total Number of Failures:

Total Number of Errors:

-------------------------

-------------------------

4505 Failures

None