Panasonic WHMDC05F3E5 User Manual

Page 7

Advertising
background image

7

10

Booster Heater

To activate or deactivate the water tank’s booster heater.

Note: If NO is selected, menu 11 is skipped.

YES

NO

11

Booster Heater Delay Timer

To delay time for the booster heater to activate while the system is heating up

the water tank.

20 minutes ~

1 hour 35 minutes

• Do not use the system during sterilisation in order to prevent scalding with hot water, or overheating of shower.
• Ask an authorised dealer to determine the level of sterilisation function field settings according to the local laws and

regulations.

12

Sterilisation

To sterilise the water tank, if required.

Note: If NO is selected, menus 13 to 15 are skipped.

YES

NO

13

Sterilisation Day & Time

To set timer for sterilisation.

(Only once a week. Operates even under a standby condition)

Monday ~ Sunday

0:00 ~ 23:50

14

Sterilisation Temperature

To set the temperature of sterilisation.

40 °C ~ 75 °C

15

Continuation of Sterilisation

To maintain heating temperature in order to complete the sterilisation.

5 minutes ~

1 hour

16

Base Pan Heater

To select whether or not to connect to the optional base pan heater.

Note: If NO is selected, menu 17 is skipped.

YES

NO

17

Base Pan Heater type

Type A - The base pan heater activates only during deice operation.

Type B - The base pan heater activates when outdoor ambient temperature is

5 °C or lower.

A

B

18

*

1,

*

2

Cool Outdoor Temperature setting

To set the outdoor ambient temperature for the AUTO mode to change from

HEAT to COOL.

5 °C ~ 25 °C

19

*

1,

*

2

Heat Outdoor Temperature setting

To set the outdoor ambient temperature for the AUTO mode to change from

COOL to HEAT.

5 °C ~ 25 °C

20

Dry Concrete

During construction to dry the concrete under a preset temperature.

Do not use this menu for any other purposes and in period other than during

construction (refer to information page).

1 day ~ 99 days

User

Remote control preparation

1 Press

.

2 Press or to set the current day.

3 Press to confirm.
4 Repeat steps 2 and 3 to set the current time.

Note:

• The current day and time need to be set in cases below:

- When the power is turned on for the first time.

- A long time has elapsed since the power was turned on the

last time.

• The current time that has been set will be the standard time for

all the timer operations.

Caution Indicator (Tank Temperature above 60 °C)

Dealer

Operation/settings to be done only by the authorised dealer/specialist.

User

Operation/settings to be done by the authorised dealer/specialist or user.

*

1

The system is locked to operate without COOL mode. It can be unlocked only by authorized installers or our authorized service partners.

*

2

Only displayed when COOL mode is unlocked (Means when COOL mode is available).

English

To

adjust initial settings

Advertising