Alto-Shaam VHES-10 User Manual

Page 16

Advertising
background image

ELECTRIC COMBITHERM

INSTALLATION MANUAL

#MN-28897

PG

. 14

1 2 • 2 0

ES

S P E C I F I C A T I O N S

®

C O M BITHERM

46-3/4"

(1186mm)

44-3/4"

(1136mm)

40-15/16"

(1039mm)

1-13/16"

(46mm)

48"

(1218mm)

45-5/16"

(1151mm)

33-1/2"

(851mm)

2-1/16" (52mm)

Water Drain

(Bottom)

51-15/16"

(1319mm)

2" (50mm)

7

6

-1

5

/1

6

"

(1

9

5

4

m

m

)

8

-1

5

/1

6

"

(2

2

6

m

m

)

7

-1

1

/1

6

"

(1

9

5

m

m

)

4

6

-1

/2

"

(1

1

5

5

m

m

)

5

4

-3

/8

"

(1

3

8

1

m

m

)

1

3

-1

/1

6

"

(

3

3

1

m

m

)

1

5

-1

3

/1

6

"

(

4

0

1

m

m

)

2

2

-1

1

/1

6

"

(5

7

6

m

m

)

11-7/8"
(302mm)
Water Drain
(Side Back)

Steam

Vents

(Top)

4-1/4"
(106mm)

Treated Water

Intake (Bottom)

Untreated Water

Intake

(Bottom)

Electrical

Connection (Bottom)

6-11/16"
(169mm)

C A PA C I T Y

FULL-SIZE PANS:

20" x 12" x 2-1/2"

Twenty-four (24)

GN 1/1:

530 x 325 x 65mm

Twenty-four (24)

GN 2/1:

650 x 530 x 65mm

Twelve (12)

FULL-SIZE SHEET PANS:*

18" x 26" x 1"

Twelve (12)

ON WIRE SHELVES ONLY

288 lb (131 kg)

MAXIMUM

VOLUME MAXIMUM

: 180

QUARTS

(228

LITERS

)

W E I G H T

NET

747 lb

(339 kg)

SHIP

1070 lb

(485 kg)

CRATE

61"

X

58"

X

53"

DIMENSIONS

: (1549 x 1473 x 1346mm)

E L E C T R I C A L

VOLTAGE

PHASE

CYCLE

/

HZ

AWG

AMPS

kW

at 208

3

50/60

3 Wire plus ground

75.6/ph

27.2

at 240

AWG 2

87.0/ph

36.1

at 380

3

50/60

4 Wire plus ground

41.4/ph

27.2

at 415

AWG 6

50.0/ph

35.7

at 440

3*

50/60

3 Wire plus ground

36.0/ph

27.2

at 480

AWG 6

43.5/ph

36.1

*

ELECTRICAL SERVICE CHARGE APPLIES

20

8-

24

0

38

0-

41

5

44

0-

48

0

D I M E N S I O N S :

H x W x D

EXTERIOR

:

54-3/8" x 46-3/4" x 48" (1381mm x 1186mm x 1218mm)

EXTERIOR

WITH

RETRACTABLE

DOOR

:

54-3/8" x 50-3/4" x 48" (1381mm x 1288mm x 1218mm)

INTERIOR

:

38-11/16" x 26-1/4" x 32-11/16" (983mm x 667mm x 830mm)

*

ADDITIONAL WIRE SHELVES REQUIRED FOR MAXIMUM CAPACITY

I N S TA L L AT I O N R E Q U I R E M E N T S
Oven must be installed level.

Hood installation is required.

Water supply shut-off valve and back-flow

preventer.

C L E A R A N C E R E Q U I R E M E N T S

LEFT

: 6" (152mm)

PLUS SERVICE ACCESS

:

18" (457mm)

RECOMMENDED

20" (508mm)

F R O M H E AT P R O D U C I N G E Q U I P M E N T

RIGHT

: 4" (102mm)

TOP

: 20" (508mm)

FOR AIR MOVEMENT

BACK

: 4" (102mm)

BOTTOM

: 5-1/8" (130mm)

FOR LEGS

WAT E R R E Q U I R E M E N T S

TWO (2) COLD WATER INLETS - DRINKING QUALITY

ONE

(1)

TREATED WATER INLET

:

3/4" NPT*

ONE

(1)

UNTREATED WATER INLET

:

3/4" NPT*

LINE PRESSURE

:

30 to 90 psi

2.8 to 6.2 bar

WATER DRAIN: 1-1/2"

CONNECTION WITH AIR GAP

* Can manifold off of one 3/4" line.

WAT E R Q U A L I T Y M I N I M U M S TA N D A R D S

USING A WATER SUPPLY NOT MEETING ALTO-SHAAM'S

MINIMUM WATER QUALITY STANDARDS WILL VOID THIS

WARRANTY. It is the responsibility of the purchaser to ensure that

incoming water supply is compliant with the specifications listed

through adequate treatment measures. Installation of the

CombiGuard™ Water Filtration System is recommended, but this

system may not address all water quality issues present.

Contaminant

Inlet Water Requirements

(untreated water)

Free Chlorine

Less than 0.1 ppm (mg/L)

Hardness

Less than 3 gpg (52 ppm)

Chloride

Less than 30 ppm (mg/L)

pH

7.0 to 8.5

Alkalinity

Less than 50 ppm (mg/L)

Silica

Less than 12 ppm (mg/L)

Total Dissolved

Solids (tds)

Less than 60 ppm

Advertising