ELECTRIC COMBITHERM

INSTALLATION MANUAL

#MN-28897

PG

. 25

®

C O M BITHERM

WAT E R S U P P LY & I N S TA L L AT I O N R E Q U I R E M E N T S

WAT E R D R A I N A G E

The oven must discharge through an indirect waste pipe by means of an air gap. The drain fitting is

supplied with a 1-1/2-inch (41mm) NPT thread.

A union is required. Install a 1-1/2-inch (41mm)

diameter connection, drain line and clamp into place.

The drain line must always be a positive gradient

away from the Combitherm oven and not more than

12-inches (305mm) before an air gap.

NOTE:

In the U.S.A., this equipment is to be
installed to comply with the Basic Plumbing
Code of the Building Officials and Code
Administrators International, Inc. [BOCA],
and the Food Service Sanitation Manual of
the Food & Drug Administration [FDA].

If several units are to be connected to one drain

pipe, the dimensions of the pipe must be sufficient

to allow an unobstructed water drain system.

1-1/4" (32mm) diameter NPT

WASTE PIPE

1-1/2" to 2" minimum diameter

(c. 38mm to 51mm)

2" (51mm)

Air Gap

1-1/2" (41mm)
diameter connection
required

1-1/2” (41mm)
diameter NPT

condensate pan
clean out