WAT E R S U P P LY & I N S TA L L AT I O N R E Q U I R E M E N T S

Flush the water line at the installation site.
Install water intake filters (provided) [see figure 1] before

connecting the oven to the water supply.
A hose connector is supplied for flexible hose connection

to the COLD water source.

PIPE SEALING TAPE

(

TEFLON

®

)

MUST BE USED AT

ALL CONNECTION POINTS.

The use of a pipe sealing

compound is not recommended.

WAT E R R E Q U I R E M E N T S

TWO (2) COLD WATER INLETS - DRINKING QUALITY

ONE

(1)

TREATED WATER INLET

:

3/4" NPT*

ONE

(1)

UNTREATED WATER INLET

:

3/4" NPT*

LINE PRESSURE

:

30 to 90 psi

2.8 to 6.2 bar

* Can manifold off of one 3/4" line

REFER TO PUBLISHED SPECIFIC WATER REQUIREMENTS

WATER DRAIN: 1-1/2"

CONNECTION WITH AIR GAP

NOTE:

BOTH TREATED AND UNTREATED WATER
CONNECTIONS MUST BE CONNECTED FOR PROPER
OPERATION OF THE OVEN. BOTH CONNECTIONS
CAN BE TREATED WATER, BUT SHOULD NEVER BE
CONNECTED TO ONLY UNTREATED WATER.

UNIONS OR FLEXIBLE LINES SHOULD BE USED TO
ALLOW FOR OVEN MOVEMENT WHEN BEING
SERVICED OR CLEANING IS NEEDED.

REFER TO DIMENSION DRAWINGS BEGINNING ON
PAGE 4 FOR PROPER INTAKE LOCATIONS.

Incoming cold water
connection

T connection

Cold water line to
untreated oven
connection

Treated cold
water to treated
connection on oven

ONE SUGGESTED

METHOD OF INSTALLATION

Water Filter

Cold water line to
filter or treatment
system

Install water
intake filters

Fig. 1