Chapter 3 — AsantéBridge 1012 Local Management

You can reset the AsantéBridge 1012 in three different ways:

❏

Cycle the power

. This resets both the bridge and hub

portions of the device. The repeater is not affected.

❏

Push the

Reset button

on the front panel. This resets

both hub and bridge.

❏

Send the

Reset system

command from the

Configura-

tion Menu

. This resets both the bridge and the hub.

Figure 3-21 Resetting the Bridge

1

Use the

arrow keys

to select the

Reset system

command.

2

Press

return

to reset the bridge.

Confirmation is required.

The command executes only

after you have confirmed your choice.

Your display will begin to cycle through the bridge power-
on diagnostics and return to the

Local Management

Menu

.

3

Enter

control-z

to return to the

Local Management Menu.

Remember that a reset:

❏

Resets the bridge and hub statistics counters to zero

❏

Erases any packets in bridge and hub memory at the
time of the reset

❏

Prevents the bridge from forwarding or filtering data
flow until the power-on diagnostics have run to comple-
tion and the bridge has completed reconfiguring

❏

Erases dynamic forwarding addresses