Panasonic CS-XE9PKUA User Manual

Page 46

Advertising
background image

46

13.2 Protection Control For Cooling & Soft Dry Operation

13.2.1 Outdoor Air Temperature Control

š The compressor operating frequency is regulated in accordance to the outdoor air temperature as shown in the

diagram below.

š This control will begin 1 minute after the compressor starts.

š Compressor

frequency will adjust base on outdoor air temperature.

13.2.2 Cooling Overload Control

š Detects the Outdoor pipe temperature and carry out below restriction/limitation (Limit the compressor Operation

frequency).

š The compressor stop if outdoor pipe temperature exceeds 141.8°F (61°C).

š If the compressor stops 4 times in 20 minutes, Timer LED blinking (F95 indicated: outdoor high pressure rise

protection).

13.2.3 Freeze Prevention Control 1

š When indoor heat exchanger temperature is lower than 32°F (0°C) continuously for 6 minutes, compressor will

stop operating.

š Compressor will resume its operation 3 minutes after the indoor heat exchanger is higher than 41°F (5°C).

š At the same time, indoor fan speed will be higher than during its normal operation.

š If indoor heat exchanger temperature is higher than 41°F (5°C) for 5 minutes, the fan speed will return to its

normal operation.

13.2.4 Freeze Prevention Control 2

š Control start conditions

o

During Cooling operation and soft dry operation

ƒ

During thermo OFF condition, indoor intake temperature is less than 50°F (10°C) or

ƒ

Compressor stops for freeze prevention control

o

Either one of the conditions above occurs 5 times in 60 minutes.

š Control

contents

o

Operation

stops

o

Timer LED blinks and “H99” indicated

13.2.5 Dew Prevention Control 1

š To prevent dew formation at indoor unit discharge area.

š This control will be activated if:

o

Outdoor air temperature and Indoor pipe temperature judgment by microcontroller is fulfilled.

o

When Cooling or Dry mode is operated more than 20 minutes or more.

š This control stopped if:

o

Compressor

stopped.

o

Remote control setting changed (fan speed / temperature).

o

Outdoor air temperature and indoor intake temperature changed.

š Fan speed will be adjusted accordingly in this control.