Panasonic CS-XE9PKUA User Manual

Page 78

Advertising
background image

78

15.4.24 F96 (IPM Overheating)

Malfunction Decision Conditions

š During operating of cooling and heating, when IPM temperature data 212°F (100°C) is detected by the IPM

temperature sensor.
Multi Models only
o

Compressor Overheating: During operation of cooling and heating, when the compressor OL is activated.

o

Heat Sink Overheating: During operation of cooling and heating, when heat sink temperature data 194°F

(90°C) is detected by the heat sink temperature sensor.


Malfunction Caused

š IPM overheats due to short circuit of hot discharge air flow.

š IPM overheats due to defective of outdoor fan motor.

š IPM overheats due to defective of internal circuitry of IPM.

š IPM overheats due to defective IPM temperature sensor.

Multi Models Only
o

Compressor OL connector poor contact.

o

Compressor

OL

faulty.


Troubleshooting




























Advertising
This manual is related to the following products: