Wiring diagrams, Com n/o n/c, Magnetic lock wiring method – Aiphone RY-18L User Manual

Page 2

Advertising
background image

NOTE:
Release contacts on the JF-2MED are from
4-pin connector included with unit.
Connect Red & Brown wires as shown.
Orange & Yellow wires are not used.
Release contacts on the JK-1MD/MED
are L/L terminals.

Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA 98005
(425) 455-0510
FAX (425) 455-0071

Toll Free Technical Support:

1-800-692-0200

E-mail [email protected]

RY-18L Instr.

0310JD

SPECIFICATIONS:
Power Source:

Supplied by master station

Mounting:

No mounting required

Terminations:

Color-coded prewired pigtails

Relay Input:

12-18V DC, Red, Gray wires, 22AWG

Relay Output:

Brown, Red, Orange wires, 18AWG

N/O Output rating:

5A at 30V DC
10A at 125V AC
3A at 250V AC

N/C Ouptut rating:

3A at 30V DC or 125V AC

Wiring:

2 conductors from monitor's door release contacts to RY-18L.
2 conductors from RY-18L to strike, with power for strike wired in series.

Dimensions (HxWxD): 1-3/4" x 7/8" x 7/16", with wires extending approx. 7-1/2"

WIRING DIAGRAMS:

A1
A2

B1
B2

S
S

DC 18V

+

-

RELEASE

(L)BRN
(L)RED

JK-1MD/MED

JF-2MED

Door

A1
A2

PS-1820UL

+

-

.

Red

Gry

Brn

Org

Yel

COM

N/O

N/C

Use Normally Open

contact for electric strike

ELECTRIC STRIKE

WIRING METHOD:

JF/JK OPEN VOICE COLOR VIDEO SYSTEM:

PS-1820UL

+

-

.

Red

Gry

Brn

Org

Yel

COM

N/O

N/C

Use Normally Closed

contact for magnetic lock

MAGNETIC LOCK

WIRING METHOD:

A1
A2

B1
B2

S
S

DC 18V

+

-

RELEASE

(L)BRN
(L)RED

Add

jumper

wire from
BRN to +

Add

jumper

wire from
BRN to +

NOTE:
Only wiring pertaining to connection of door
release relay is shown here.
For complete system information, please
consult the main system installation manual.

JK-1MD/MED

JF-2MED

+ -

LOCK

POWER

+ -

LOCK

POWER

Advertising