Warning – Nieco JF64-BG User Manual

Page 11

Advertising
background image

11

C.2 lighting Procedures

1. Broiler is

centered under

hood and

plugged in

2. Gas valve is

open when

handle is in line

(parallel to) the

pipe

3. Turn ventilation

system on

The JF64-BG is equipped with automatic ignition. When the broiler is turned on, a hot surface ignitor turns on 5 sec-

onds before the flow of gas. Gas then flows to all of the burners. If the burners are not lit within 10 seconds, the con-

trol will reset and try again for 10 seconds. This occurs 3 times. If the broiler does not light after the third attempt, the

ignition failure light will flash and the main on/off switch must be cycled to repeat the procedure. If this still doesn’t light

the broiler, see the MANUAL IGNITION instructions.

WaRnInG

THe VenTIlaTIon sYsTeM MUsT be

on aT all TIMes DURInG bRoIleR

oPeRaTIon. oPeRaTInG bRoIleR

WITHoUT PRoPeR VenTIlaTIon Is a

seVeRe fIRe HaZaRD.

noRMal IGnITIon

PRe-lIGHTInG PRePaRaTIon

Nieco Corporation - Model JF64-BG

1. Turn the MaIn PoWeR sWITCH on.

1.

2.

2. Allow broiler to heat for 45 minutes before cooking.

ManUal IGnITIon

1. Remove the discharge awning. Turn the MaIn PoWeR

sWITCH on. Hold a lighter/match to the first upper burner

on the discharge end until the burner lights. Once the first

burner is lit, verify that all burners have ignited.

Advertising