CaUTIon

all electrical connections must be

in accordance with local electrical

codes and any other applicable

codes.

CaUTIon

Do not operate the broiler at gas

pressures other than those stated

here. Doing so will affect the opera-

tion of your broiler.

Nieco Corporation - Model JF64-BG

G. sPeCIfICaTIons

AUTOMATIC BROILER

Model JF63-BG

DIMensIons

Inches

mm

Length

42.34

1075

Height (on stand)

57.62

1463

Width

34.73

882

eneRGY

Gas Models, Natural or LPG:

Average usage:

65,000 BTU/hour

Connection size: 3/4” NPT

Electric connection: 208V 10.8A 1Ø

WeIGHT

600 lbs 272 Kg

oPTIons

Legs (no stand)

Spare parts kit

Dual Belt

mm

L

1075

H

57.66 1465

W

1040

E

272 Kg

!

'

'

'

'

'

'

'



mm

L

1075

H

57.66 1465

W

1040

E

272 Kg

!

'

'

'

'

'

'

'