Warning – Nieco JF63-BG User Manual

Page 7

Advertising
background image

7

b.6 Gas Connection- 3/4” n.P.T.

At rated input the gas supply should deliver a minimum pressure of at least 15 mbar (6" water column)

at the broiler connection for natural gas. Incoming gas supply pressure must not exceed 50 mbar (14"

water column).

note: The installation of this appliance must conform with local codes, or in the absence of local codes,

with the National Fuel Gas Code, ANSI Z223.1, Natural Gas Installation Code, CAN/CGA-B149.1

including:

1. The appliance and its individual shutoff valve must be disconnected from the gas supply

piping system during any pressure testing of that system at test pressures in excess of

1/2 psi (3.45 kPa).

2. The appliance must be isolated from the gas supply piping system by closing its

individual manual shutoff valve during any pressure testing of the gas supply piping

system at test pressures equal to or less than 1/2 psi (3.45 kPa).

By public initiative, the State of California has adopted legislation (Proposition 65) which

requires manufacturers of many types of products, including gas appliances, to warn consumers

of their products that contain chemicals or produce substances listed by the State of California

to either cause cancer, birth defects or other reproductive harm.

Nieco Corporation - Model JF63-BG

For safety in the kitchen area, and to insure maximum service life, it is vitally important to correctly install

connectors. The connector shall comply with the Standard for Connectors for Moveable Gas Appliances,

ANSI Z21.69 or CAN/CGA-6.16 and a quick disconnect device that complies with the Standard for Quick-

Disconnect Devices for use with gas fuel, ANSI Z21.41 or CAN1-6.9

In order to avoid sharp kinks or excessive bends that could have a damaging effect on the connector, it

may be necessary to attach pipe elbows in order to bring the connector into its proper plane. For easy

movement of the appliance, the connector should be installed with a "lazy" loop for minimum tension.

note: Gas appliances should be disconnected prior to maximum movement. (Minimal movement

is possible to connect hose.)

b.7 Installing Gas appliance Connectors and flexible Gas lines Correctly

WaRnInG

If not installed, operated and maintained in accordance with the manufacturers instructions, this

product could expose you to substances in fuel or from fuel combustion which can cause cancer,

birth defects or other reproductive harm.

Advertising