CeilingVIEW 70 PTZ - Document 010-2304-000 Rev.E

Page 6 of 14

FRONT

IMAGE FLIP

IR SELECT

COVER

PLATE

RETAINER
SCREWS

COVER
PLATE

COVER

PLATE OFF











If you are using a control system (i.e. Crestron or AMX), plug the
Cat.5 cable from the RS-232 IN jack on the camera to your control
system using the Cat.5 to DB9 serial adapter supplied by Vaddio. If
you are controlling more than one camera, plug the Cat.5 cable from
the RS-232 OUT jack on the first camera to the RS-232 IN jack on
the second camera. Repeat procedure if third camera is to be used.

Please refer to Figure 10 for this procedure.

• Camera must be disconnected from electrical power.

• Remove the 4 cover plate retainer screws.

• Carefully lift off cover plate while threading the IR cable back through hole.

• Looking between the rear of the EVI-D70 camera body and the interconnect

circuit board; locate the 2 switches (it may be necessary to slightly tilt the
camera assembly to get the best view of the switches).

• The default setting for the image flip function is ON.

• The default setting for IR select is 1. If this to be camera number 2 in a 2

camera system, set this switch to position 2. If this camera is number 3 in a 3
camera system, set switch to position 3.

• Carefully thread the IR cable back through the cover plate and secure plate to

camera enclosure using the 4 retaining screws.







Figure 9:
RM-EV100 IR Remote Controller

• Power on/off

• Camera Select:

1, 2, 3

• Focus:

Auto, Manual (Near & Far)

• Zoom:

Slow – Tele, Wide
Fast – Tele, Wide

• Data Screen

On Screen Display

• Back Light:

Back Light Compensation

• Pan-Tilt:

Left, Right, Up, Down, Reset

• Home:

Home/Centered Position

• Position:

Preset,

Reset

• Presets:

6 (1 through 6)

L/R Direction Set:

Std, Rev

Control
Systems

CHANGING CAMERA
DEFAULT SETTINGS

Figure 10: Cover Plate Removal and default settings access