Vaddio supplies this control specification for the CeilingVIEW 70 PTZ camera.
This VISCA control set (as used in Sony EVI cameras) is used in conjunction with
additional Vaddio control commands (see comment section on Table 1) for added
functionality of the camera lift.

Communication Speed: 9600 bps (default)
Start bit:

1

Stop bit:

1

Data bits:

8

Parity:

None

The control codes for the CeilingVIEW 70 PTZ are the same codes used with the
EVI-D70 pan/tilt/zoom camera. Vaddio is not translating these codes and does
not add any translation or memory capability to enable use of the EVI-D70 camera
as a main or auxiliary camera with videoconferencing system codecs or the
associated IR remote controllers of the codecs.

For best control results, use the provided RM-EV100 IR Remote Controller or the
VISCA Commands (detailed in Table 1 below) with an external control system.

Table 1: VISCA Command List (Partial)

RS-232

Command Set

Command

Command Packet*

Comments

AddressSet

Broadcast

88 30 01 FF

Address setting

IF_Clear

Broadcast

88 01 00 01 FF

I/F Clear

CommandCancel

8x 2p FF

p: Socket No.(=1or2)

On

8x 01 04 00 02 FF

Power ON

CAM_Power

Off (Standby)

8x 01 04 00 03 FF

Power OFF

Stop

8x 01 04 07 00 FF

Tele(Standard)

8x 01 04 07 02 FF

No

Wide(Standard)

8x 01 04 07 03 FF

Tele(Variable)

8x 01 04 07 2p FF

p=0(Low)~7(Fast)

Wide(Variable)

8x 01 04 07 3p FF

CAM_Zoom

Direct

8x 01 04 47 0p 0q 0r 0s FF

pqrs: Zoom Position

D-Zoom On

8x 01 04 06 02 FF

Digital Zoom ON/OFF

CAM_Dzoom

D-Zoom Off

8x 01 04 06 03 FF

Stop

8x 01 04 08 00 FF

Far(Standard)

8x 01 04 08 02 FF

Near(Standard)

8x 01 04 08 03 FF

Far(Variable)

8x 01 04 08 2p FF

p=0(Low)~7(High)

Near(Variable)

8x 01 04 08 3p FF

Direct

8x 01 04 48 0p 0q 0r 0s FF

pqrs: Focus Position

Auto Focus

8x 01 04 38 02 FF

AF ON/OFF

Manual Focus

8x 01 04 38 03 FF

CAM_Focus

Auto/Manual

8x 01 04 38 10 FF

RS-232
COMMAND LIST

Communication
Specification

*Communication Example:
For the VISCA Packet “8x 01 04 07 03 FF”
(CAM_Zoom_Wide), “x” corresponds with
the number and order of the camera in the
control chain (daisy chain) where x = 1 for
the first camera, x = 2 for the second
camera, etc…

Control