Setting up and programming – Vaddio ControlVIEW XHD User Manual

Page 8

Advertising
background image

ControlVIEW XHD

ControlVIEW XHD Manual 341-917 Rev. C

Page 8 of 24

Setting Up and Programming

First Time Set-up with the ControlVIEW XHD:
ControlVIEW XHD was designed to be exceptionally easy to program and use. All of the Vaddio
standards for transmitting RS-232 control over Cat. 5 cabling are in this manual and available free of
charge from the Vaddio website.

Getting Started:
1.
Connect all of the cameras, monitors and peripheral devices to ControlVIEW XHD. The back panel

has standard VGA connectors, and Vaddio offers four different break out cables for the inputs/outputs;
one for SD video (composite on inputs & outputs, Y-C also on inputs) and three cables (7 in., 3 ft. or 6
ft.) for component HD/SD video (YPbPr).

2. When applicable, connect the RS-232 port on the ControlVIEW XHD to an available serial port on a

control system (i.e. Crestron®, AMX®, etc.).

3. Trigger Devices: Connect wires from the trigger devices (i.e. StepVIEW mat, AutoVIEW IR, MicVIEW,

etc.) to each designated port – one wire will go to the trigger input, the other will go to one of the “G”
(Ground) ports. See the specific trigger devices for additional information on installation. Make note
as to what trigger device is connected to which specific trigger port on the back of ControlVIEW XHD.

NOTE: The dual outputs of the ControlVIEW XHD will deliver the same resolution.

Once all of the inputs, outputs, trigger devices and the PowerRite power supply are connected, plug the
AC cord into an outlet. ControlVIEW XHD will boot up and scan for cameras. After boot up, a menu will
appear on the blue LCD screen.

Configuring Output Resolutions:
On the LCD screen, a chevron (>) will be
displayed next to the menu item that is currently
selected. Press the Arrow Down Button (

↓)

adjacent to the LCD screen, until the chevron is
next to “VIDEO OUTPUT MENU” and then press
the SELECT button. Arrow down to the
appropriate resolution that is compatible with
your video monitor, then press the SELECT
button. Then, press the CANCEL button to exit
to the previous menu.

NOTE: For additional information on the menu tree structure, see pages 13 to 15.

Configuring Input Resolutions:
From the Main Menu, press the down arrow button, to move the chevron to VIDEO INPUT MENU, and
then press the SELECT button. If all input devices have the same resolution (i.e. 1080i / 59.94), then
select ALL PORTS. If not all inputs have the same resolution, then press the down arrow button to the
first input with a video device attached, and press SELECT. Choose the appropriate video resolution for
the video device connected to the input, and then press SELECT. Press the CANCEL button to exit the
resolution setting for the input. Repeat the process for all video inputs.

After all inputs/outputs have been set, touch the arrow up to RESCAN VIDEO. Press SELECT. At
START press SELECT again. All video resolutions will now be configured. Any time an input or output
source is changed you will need to perform the RESCAN VIDEO function for the new settings to take
effect.

Configuring PTZ Cameras:
After configuring the input and output resolutions, arrow down to, and select CAM SEARCH MENU on the
LCD screen. Arrow down to PORT 1, and press select. Next, select the type of camera that is connected
to Port 1 (i.e. if a Canon PTZ camera is connected, then select CANON ONLY). Repeat the process for
each port, based on the type of camera that is connected. For Vaddio PTZ cameras, select AUTO
SEARCH.

ControlVIEW XHD

V01.02.00

MAIN MENU

>Rescan Cameras

Rescan Video

Video Output

Video Input Menu