Vaddio REVEAL User Manual

Page 16

Advertising
background image

REVEAL IN-Wall Cameras

REVEAL IN-Wall Camera Manual Document Number 342-0059 Rev. A

Page 16 of 28

Rear Panel Connectivity (left to right):







Power Input:

5.5mm OD x 2.5mm ID, Positive Center 12 VDC, 1.0 Amp, Power Jack
Use with Provided 12 VDC, 1.0 Amp Power supply only.

RS-232 IN:
Control input from Joystick Controller (i.e. Precision Camera Controller, ProductionVIEW HD, etc…), control system or
codec. This input provides for camera control other than CCU controls.

RS-232 OUT (To Camera):
Attach to REVEAL camera RS-232 Port for CCU Control. The IR OUT, IR Forwarding feature is not processed by the
CCU Controller.

Tally Contact:

Local front panel tally - lights up Blue LED on front panel when shorted.

Camera Settings:
10-position dip switch for added functions and future control parameters.



Instructions for using the Quick-Connect CCU Controller with the REVEAL Camera:






Power Up Order: When using the Quick-Connect CCU, power up the REVEAL camera first, then the Quick-Connect

CCU. The Quick-Connect CCU and ProductionVIEW Controllers will auto-detect the camera attached, so naturally
the REVEAL has to be ON first.

Monitor Set Up: Verify that the video monitor used in conjunction with the Quick-Connect CCU is set up correctly

and is delivering accurate color reproduction.

Initial CCU Set Up: Adjust the iris level of the camera so that brighter areas are not washed out. Then adjust the

Pedestal level so that the black levels are not too dark, and not too light. When those levels are set, adjust the Red &
Blue Gain, Gamma, Detail, Knee and Chroma. NOTE: Gain (next to Iris) should be left at 0 (zero), unless lighting is
inadequate, then turn it to a level where the signal brightness is at an appropriate level. Higher Gain levels add
additional noise (grain) to the video signal.

IR Output Switch 4: When operating the REVEAL camera connected directly to the Quick-Connect CCU, set the IR

Output dip switch on the front of the REVEAL to the OFF position. If it is not turned off, it may interfere with proper
operation of the PTZ camera.


See the next page for a system configuration diagram using the SR Series Interfaces with the CCU controller.