UXHD CrossPoint Installation and User Guide 341-929 Rev. A Page 9 of 12

Appendix 1: Communication Specification and Pin-outs for the UXHD CrossPoint
Vaddio uses simple control protocols to accomplish custom programming with the ProductionVIEW HD. The
Communication Specification, API and Programming Language are listed below and definitions are listed on
the next page. Note: All commands must be followed by a carriage return.

Communication Specification

Control Port - RS-232 on DB-9F Connector

Communication Speed: 9600 bps (default)
Start bit: 1
Stop bit: 1
Data bits: 8
Parity: None
No Flow control

PIN# Signal

2) TXD
3)

RXD

5)

GND

All other pins - Unused

API and Programming Language

+----------------------------------------------------------------------------+
| Vaddio UXHD CrossPoint |
+----------------------------------------------------------------------------+
|? - This menu |
+--------------- System -----------------------------------------------------+
|Power x- Power(On/Off) |ClearMem - Clear Memory |
|SerialEcho x- Echo Serial (Yes/No) |Reset - 'CPU'Reset |
|Version - Firmware Version |Config - List Config Settings|
|EEDump - Display Config EEProm | Input x- Input (1/2) |
| | Output x- Output (1/2) |
+----------------------------------------------------------------------------+

Command Structure Definitions

Command Parameters

Description

ClearMem ClearMem(cr)

Clear

Memory

Config

Config(cr)

Display system configuration

EEDump EEDump(cr)

Display Configuration EEProm

Input Input

1/2(cr)

Select Input port

Output Output

1/2(cr)

Select Output port

Power

Power On/Off(cr)

Power system On/Off

Reset Reset(cr)

Soft System reset

SerialEcho SerialEcho

On/Off(cr)

Serial Echo On/Off

Version

Version(cr)

Display System Version information