2. Technical Gas Data

a. Gas Specifications

* Measured at outlet side of gas valve pressure tap when gas valve is on.

b. Gas Connections

Inlet connection ------------------1/2” N.P.T.
Inlet supply size ------------------1/2” N.P.T. (minimum)
Btu/hr input (per dryer) ---------160,000 (40,320 kcal/hr) ADG-60D

140,000 (35,280 kcal/hr) ADG-60DH

1) Natural Gas

Regulation is controlled by the dryer’s gas valve’s internal regulator. Incoming supply pressure
must be consistent between a minimum of 6.0 inches (14.92 mb) and a maximum of 12.0 inches
(29.9 mb) water column (W.C.) pressure.

2) Liquid Propane (L.P.) Gas

Dryers made for use with L.P. gas have the gas valve’s internal pressure regulator blocked open so
that the gas pressure must be regulated upstream of the dryer. The pressure measured at each
gas valve pressure tap must be a consistent 10.5 inches (26.1 mb) water column. There is no
regulator or regulation provided in an L.P. dryer. The water column pressure must be regulated at
the source (L.P. tank) or an external regulator must be added to each dryer.

* Drill Material Size (D.M.S.) equivalents are as follows:

Natural Gas .................. #23 = 0.1540” (3.9116 mm).

#29 = 0.1360” (3.4544 mm).

Liquid Propane Gas ..... #42 = 0.0935” (2.3749 mm).

#48 = 0.0760” (1.9304 mm).

TYPE OF GAS

NATURAL

LIQUID PROPANE

Manifold Pressure*

3.5 inches W.C.

8.7 mb

10.5 inches W.C.

26.1 mb

In-Line Pressure

6.0 - 12.0 inches W.C.

14.92 - 29.9 mb

11.0 inches W.C.

27.4 mb

Shaded areas are stated in metric equivalents

TYPE OF GAS

L.P.

Conversion

Kit

Part Number

ADC

MODEL

NUMBERS

BTU

Per Hour

Rating

kcal/hr

Rating

Natural

Liquid Propane

Qty.

D.M.S.*

Part

Number

Qty.

D.M.S.*

Part

Number

AD-60D

160,000

40,320

3

#29

140820

3

#48

140804

881048

AD-60DH

140,000

35,280

2

#23

140856

2

#42

140810

881049

Shaded areas are stated in metric equivalents