Gas models only, Electric models only – American Dryer Corp. AD-60 User Manual

Page 56

Advertising
background image

52

C. Blower motor (only) is not operating...

1. Failed impellor (fan/blower) motor contactor (relay).

2. Failed blower (impellor/fan) motor.

D. Both drive and blower motors are not operating (indicator light is on)...

1. Fault with L1 termination at reversing timer (for reversing models only).

2. Failed drying timer.

E. Reversing drive motor operates in one (1) direction only, stops and restarts in same direction

(for reversing models only)...

1. Failed reversing contactor (relay).

2. Failed reversing timer.

F.

Heating unit is not operating (ALL temperature selections)...

GAS MODELS ONLY

1. Fault in sail switch circuit...

a. Sail switch is out of adjustment and/or failed.

b. Sail switch is not closing or fluttering...

1) Check blower (impellor/fan) motor and rotation direction.

2) Restriction in location exhaust system.

2. Tripped burner manual reset hi-limit thermostat.

3. Tripped lint compartment manual reset (225º F [107º C]) safety hi-limit thermostat.

4. Failed heat selector switch.

ELECTRIC MODELS ONLY

1. Fault in sail switch circuit...

a. Sail switch is out of adjustment and/or failed.

b. Sail switch is not closing or fluttering...

1) Check blower (impellor/fan) motor and rotation direction.

2) Restriction in location exhaust system.

2. Failed oven hi-limit circuit.