OPL MODELS

1. To start the dryer:

a. Microprocessor controller (computer) dryers...

1) The light emitting diode (L.E.D.) display will read “FILL.”

2) Press the “E” on the keyboard (touch pad).

3) The L.E.D. display will quickly show “Ld30,” “LC04,” and “F180.” The dryer will start, and the

L.E.D. display will show “dr30.”

b. Dual timer dryers

1) Turn drying timer knob for a time of 20 minutes.

2) Select “HI TEMP.”

3) Push “Push To Start” switch.

4) To stop dryer, open the main door.

L. SHUT DOWN INSTRUCTIONS

If the dryer is to be shut down (taken out of service) for a period of time, the following must be performed:

1. Discontinue power to the dryer either at the external disconnect switch or the circuit breaker.

2. Discontinue the heat supply:

a. GAS MODELS...discontinue the gas supply.

1) SHUT OFF external gas supply shutoff valve.

b. STEAM MODELS...discontinue the steam supply.

1) SHUT OFF external (location furnished) shutoff valve.