Vaddio WallVIEW PRO HD-1 User Manual

Page 7

Advertising
background image

WallVIEW PRO HD1 Installation and User Guide 341-661 Rev. D Page 7 of 14

Step 9: For HDX 9000 Series Installs Requiring IR Pass-Thru
Connect a two-conductor wire to the connectors of both the
Polycom HDX codec and Quick-Connect Universal PRO rack
mount box. Ground from the Universal PRO should be
terminated to the “-“ port on the HDX 9000 Series codec’s IR input.
The SIG port on the Universal PRO should be terminated to the
square wave symbol. See adjacent drawing for additional detail

Connect the IR output from the Quick-Connect Universal PRO to
either the IR spring cage IR input on an HDX series codec (where
available) or a Xantech™ IR probe (compatible models: 282MRP
or 283M). The white striped wire on the IR Probe is the Signal
and the black wire is Ground.









Step 9: For HD1 IR Pass-Thru on HDX 7000 and 8000 Series Codecs
Using the Optional RJ-45 to DB-9 adapter (998-1006-232) with the system, strip and terminate the single wire
coming out of the back of the adapter, and connect it to the Phoenix-type connector supplied with the Quick-
Connect PRO. The wire needs to be terminated to the Signal “SIG” pin on the back of the Quick-Connect
PRO.


















Step 9: For TANDBERG Video Switch IR Pass-Thru
If connecting a Xantech IR Probe to the IR output of the Quick-
Connect Pro, the white striped wire on the probe should be
connected to the signal “SIG” terminal and the ground, or black
wire to “GND”. Attach the probe over the IR window of the codec.
Make sure the dipswitch is in the correct position






Figure 9:

Wiring Configuration for

IR Forwarding feature

(optional)

Figure 10:

Required wiring configuration

for IR Forwarding from the camera IR
port to codec. Note: There is no IR port
on the front of the HDX 7000 and 8000
series codecs. The IR receiver on these
codecs is imbedded in the camera.

RS-232 Cat. 5

Single wire from the back of the Optional
RJ-45 to DB-9 adapter (998-1006-000),
connected to the IR “SIG” (signal) port via a
Phoenix-type connector

Figure 11:

Terminating Xantech

Probe cable to 2-position Phoenix
type connector

Advertising