9 mcc_gammavalue (0x9d), Gamma value, Mcc_gammavalue (0x9d) – Beijer Electronics SCOM Protocol EN User Manual
Page 34

Command Reference
34
Beijer Electronics, MAEN975
6.9 MCC_GAMMAVALUE (0x9D)
Gamma Value
Sets or queries the gamma value.
Supported since Firmware Version
MT230 Nautic Monitor: 1.0
Command Stream
Response Message (Acknowledge)
Maximum Lr for this Command
11
0
1
2
3
4
5
6
7...7+[LEN]-1 7+[LEN]
0x07
ADR
0x4D
0x43
0x43
LEN
ICHKH 0x9D
Param ICHKD
Param: ABSOLUTE
Value:
“0”: Linear
“1”: CRT
Type:
One-digit ASCII-encoded hexadecimal number
Length:
1
Description: New gamma value
Param: RESET
Value:
“R” or “r” (0x52 or 0x72)
Type:
ASCII character
Length:
1
Description: Reset the gamma setting to an internally predefined value
Param: QUERY
Value:
“?” (0x3F)
Type:
ASCII character
Length:
1
Description: Query the current gamma value
0
1
2
3
4
5
6
7...7+[LEN]-1
7+[LEN]
0x06
ADR
0x4D
0x43
0x43
LEN
ICHKH 0x9D Param
Ret
ICHKD
Ret
Value:
“0”: Linear
“1”: CRT
Type:
One-digit ASCII-encoded hexadecimal number
Length:
1
Description: Current gamma value