Beijer Electronics SCOM Protocol EN User Manual
Page 68
Advertising

Command Reference
68
Beijer Electronics, MAEN975
Example
Get the serial interface configuration of the monitor at address 0.7 (group 0, address
7):
According to the data returned by the monitor at address 10.7 (group 0, address 7),
the serial interface is configured as RS232:
0
1
2
3
4
5
6
7...8
9
0x07
0x07
0x4C
0x41
0x55
0x02
0x0D
0x01
0x10
0xEE
0
1
2
3
4
5
6
7
8
0x06
0x07
0x4C
0x41
0x55
0x01
0x0F
0x00
0xFF
Advertising