Example
Read the lower backlight level range limit configuration for the monitor at address
0.7 (group 0, address 7):

According to the data returned by the monitor at address 0.7 (group 0, address 7),
the lower backlight level range limit is 0 (0x00). This means, the user cannot adjust
the backlight level lower than the ECDIS backlight level, using the front panel key:

0

1

2

3

4

5

6

7...8

9

0x07

0x07

0x4C

0x41

0x55

0x02

0x0D

0x01

0x22

0xDC

0

1

2

3

4

5

6

7

8

0x06

0x07

0x4C

0x41

0x55

0x01

0x0F

0x00

0xFF