Battery care – NaceCare Solutions TTV678 User Manual

Page 21

Advertising
background image

233890 05/11 (A03)

21

Battery Care

To ensure your machine remains at its maximum efficiency and prolong your battery life, please follow
the simple steps below:

Under normal daily usage:
Recharge batteries after each use regardless of machine operation time
(see page 19)

Showing location of Viewing panel for charging-light sequence.

Yellow:- Charging Normally, 23 hours MAX

Yellow Flashing:- Charging Finished, (Trickle Charging)

Green:- Fully Charged

Red:- Remove Mains Supply

Failure of charger profile – corrective action replace faulty battery

Charging stopped. time out timer expired (27hrs) corrective action
replace faulty batteries

Internal charger failure – corrective action replace charger

Recharge the machine fully after its last use. Do not leave the machine in a discharged state.

Over temperature – corrective actions ensure charger ventilation
slot are free of debris and ventilation channel has no restrictions.

Advertising