Trouble-shooting, Problem cause solution – NaceCare Solutions TTV678 User Manual

Page 23

Advertising
background image

233890 05/11 (A03)

23

Trouble-Shooting

Diagnostic software is available via your service engineer.

Failure to rectify the problem or in the event of a breakdown contact your
Numatic dealer or the Numatic Technical helpline +44 (0)1460 269268

PROBLEM

CAUSE

SOLUTION

Machine will not operate

Missing or blown fuses

Key in the ‘OFF’ position

Low battery charge

Machine isolator button in ‘OFF’ mode

Machine is connected and charging

Fit or replace fuse (page 7)

Turn key to ‘ON’ position (page 7)

Charge batteries (page 19)

Reset isolator (page 15)

Take off charge (page 19)

Vacuum will not operate

Floor tool in raised position

Waste water tank full

Lower floor-tool (page 12)
Empty waste water tank (page 17)

Poor water pick-up

Waste-water tank full

Clogged / blocked vacuum hose

Loose hose connections
Debris basket filter cloogged/blocked
Separator filter clogged / blocked
Poor separator seal

Damaged separator seal

Damaged / split vacuum hose
Damaged floor-tool blades
Low battery charge

Empty waste-water tank (page 17)

Remove and clean (page 17)

Push tight connections (page 16)

Remove and clean (page 17)

Remove and clean (Page 17)
Clean and refit (page 17)
Renew (contact service dept)

Renew (contact service dept)

Renew (contact service dept)

Recharge batteries (page 19)

No brush / scrub function

No brushes fitted
Brush deck raised

Check and fit (page 9)
Lower brush deck (page 12)

Little or no water flow

Clean-water tank empty
Clean-water tank filter blocked/ clogged
Incorrect water flow setting
Brush deck raised

Fill clean-water tank (page 10)

Remove and clean (17)

Adjust as desired (Page 13)

Lower brush deck (page 12)

Little or no dosing solution flow

Chemical dosing tank empty
incorrect dosing flow setting

Fill dosing-tank (page 11)

Adjust as desired (page 13)

Machine just ‘stops’ while

operating

To much load on the brush system

Reset the machine using the key and

decrease the brush load to best suit
the floor type (page 14)

Machine will not operate in reverse

Floortool in lowered position

‘Causes Battery Indicator to Flash’

Raise floortool (page 12)

Advertising