Suction-piping checklist – Goulds Pumps 3393 - IOM User Manual

Page 33

Advertising
background image

Installation

Suction-piping checklist

Performance curve reference

CAUTION:
Vary the capacity with the regulating valve in the discharge line. Never throttle the flow from the suction
side. This action can result in decreased performance, unexpected heat generation, and equipment
damage.

Net positive suction head available (NPSH

A

) must always exceed NPSH required (NPSH

R

) as

shown on the published performance curve of the pump.

NOTICE:For optimum life a suction strainer must be permanently installed in the suction piping
to prevent debris from entering the pump and causing it to seize. See below.

Suction-piping checks

Check

Explanation/comment

Checked

Check that piping is free of dirt

Dirt or debris can damage the

and foreign objects.

pump on startup.

Check that elbows in general do

This minimizes the risk of cavita-

not have sharp bends.

tion in the suction inlet of the
pump due to turbulence.

Check that the suction piping is

The suction piping must never

one or two sizes larger than the

have a smaller diameter than the

suction inlet of the pump.

suction inlet of the pump.

Install an eccentric reducer be-
tween the pump inlet and the
suction piping.
Check that the eccentric reducer

at the suction flange of the pump
has the following properties:
• Sloping side down
• Horizontal side at the top
When suction strainers or suction Suction strainers help to prevent
bells are used, check that they are clogging.
at least three times the area of the The strainer should be no coarser

suction piping.

than 40 mesh – 60 mesh or higher
is preferred. Strainers must have
a minimum free open area of
300% of nominal pipe diameter.
Velocities should be limited to 6-7
ft/s to keep the pressure drop
across the strainer to a minimum.
The pressure drop across the
strainer should be monitored and
the strainer cleaned if the pres-
sure drop exceeds 5 psi (0.34 bar)
or NPSHR is not adequate.

If more than one pump operates

This recommendation helps you to

from the same liquid source,

achieve a higher pump perfor-

check that separate suction-piping mance.
lines are used for each pump.
If necessary, make sure that the

suction piping includes a drain
valve and that it is correctly in-
stalled.

Liquid source below the pump

Check

Explanation/comment

Checked

Make sure that the suction piping

This helps to prevent the occur-

is free from air pockets.

rence of air and cavitation in the
pump inlet.

Model 3393 Installation, Operation, and Maintenance Manual

31