Maintenance

Guidelines for i-ALERT™ Condition Monitor disposal

Precautions

WARNING:

• Never heat the condition monitor to temperatures in excess of 300°F (149°C). Heating to these

temperatures could result in death or serious injury.

• Never dispose of the condition monitor in a fire. This could result in death or serious injury.

Guidelines

The battery contained in the condition monitor does not contain enough lithium to qualify as
reactive hazardous waste. Use these guidelines when disposing of the condition monitor.

• The condition monitor is safe for disposal in the normal municipal waste stream.

• Adhere to local laws when you dispose of the condition monitor.

Pre-assembly inspections

Guidelines

Before you assemble the pump parts, make sure you follow these guidelines:

• Inspect the pump parts according to the information in these pre-assembly topics before

you reassemble your pump. Replace any part that does not meet the required criteria.

• Make sure that the parts are clean. Clean the pump parts in solvent in order to remove oil,

grease, and dirt.

NOTICE:
Protect machined surfaces while you clean the parts. Failure to do so may result in
equipment damage.

Preassembly inspections

Replacement guidelines
Casing check and replacement
Inspect the casing and diffusers for cracks and excessive wear or pitting. Thoroughly clean o-
ring surfaces and alignment fits to remove corrosion and debris.
Repair or replace these parts if you notice any of these conditions:

• Localized wear or grooving that is greater than 1/8 in. (3.2 mm) deep

• Pitting that is greater than 1/8 in. (3.2 mm) deep

74

Model 3393 Installation, Operation, and Maintenance Manual