Iii - engineering data, Appendix iii, Engineering data – Goulds Pumps 3409 - IOM User Manual

Page 59: Casing data, Stuffing box data, Impeller design data, Shaft and bearing data

Advertising
background image

APPENDIX III

3409 IOM 11/04

59

ENGINEERING DATA

Pump Size

°

6x10-22

°

8x12-21

°

8x12-22M

°

8x12-22L

8x12-27

CASING DATA

(All Dimensions in Inches)

­

125# FF Std.

Max. Suction Pressure (PSIG)

75

75

75

75

Not

Available

ASA Flanges

Max. Working Pressure (PSIG)

300

300

300

300

Max. Hydrostatic Test Pressure (PSIG)

450

450

450

450

Casing Material

Cast Iron

Cast Iron

Cast Iron

Cast Iron

¬

250# FF

Max. Suction Pressure (PSIG)

200

200

200

200

200

®

ASA Flanges

Max. Working Pressure (PSIG)

400

400

400

400

400

Max. Hydrostatic Test Pressure (PSIG)

¯

600

600

600

600

600

Casing Material

Ductile Iron

Ductile Iron

Ductile Iron

Ductile Iron

Ductile Iron

Casing Wall Thickness

.625

.625

.625

.625

.625

STUFFING BOX DATA

Bore

5.125

5.125

5.125

5.125

5.125

Depth

4.812

4.812

4.812

4.812

4.812

Seal Cage Width

.75

.75

.75

.75

.75

Packing No. Rings/Size Sq.

6/.625

6/.625

6/.625

6/.625

6/.625

Shaft Sleeve O.D.

3.875

3.875

3.875

3.875

3.875

Mechanical Seal Size (Type 8-1)

3.875

3.875

3.875

3.875

3.875

Å

{

Mechanical Seal

{

Major Dia.

4.125

4.125

4.125

4.125

4.125

Size (Type 8-1B)

Minor Dia.

3.875

3.875

3.875

3.875

3.875

IMPELLER DESIGN DATA

Number of Vanes

6

6

5

6

6

Inlet Area (Sq. Inches)

59

35.7

61

80

82.4

Inlet Velocity per 100 GPM (Ft/Sec)

.54

.90

.53

.40

.37

Maximum Diameter

23.0

21.8

20.5

23.0

27.0

Minimum Diameter

12.0

12.5

12.5

12.0

20.0

Maximum Sphere

1.30

1.00

1.32

1.60

1.50

WR^2 for Maximum Diameter (Lbs-Ft^2)

56

49

50

59

185

Wear Ring Clearance — Dia. BRZ Impellers

.016-.019

.016-.019

.016-.019

.016-.019

.016-.019

Wear Ring Clearance — Dia. Cl and SS Impellers

.025-.028

.025-.028

.025-.028

.025-.028

.025-.028

SHAFT AND BEARING DATA

At Coupling

3.125

3.125

3.125

3.125

3.125

Thru Impeller and Sleeves

3.311

3.311

3.311

3.311

3.311

Shaft Span

Bearing to Bearing Centerline

35.800

35.800

35.800

35.800

40.500

Ball Bearing

Inboard

6316

6316

6316

6316

6316

Outboard

21316

21316

21316

21316

21316

Frame Group

S

S

S

S

M

¬

With 250# FF flanges refer to pump as H6x10-22.

­

Flange dimensions are in accordance with ANSI A21.10,
AWWA C110 and ANSI B16.1 Class125.

®

Flange dimensions are in accordance with ANSI B16.1 Class
250 except flanges are flat faced.

¯

The hydrostatic test will be in accordance with the latest
edition of the Hydraulic Institute Standards, test will be
maintained for a minimum of 10 minutes.

°

6x10-22, 8x12-21, and 8x12-22M/L are standard with
125# FF suction and 250# FF discharge flanges.

±

Balanced mechanical seals have a major and a minor
diameter as listed.

7

Advertising