Vii - field test report form, Field test report – Goulds Pumps 3409 - IOM User Manual

Page 67

Advertising
background image

Field Test Report

Date ________________

Pump Size _______________________ Pump Type _______________________

RATING: GPM _______________ Head ____________ RPM _____________

Pump Serial Number _______________ Impeller Diameter (in.) ______________

Suction gauge pipe size ___________________________ inches

Manufacturer’s Pump Curve Number ___________________________________

Discharge gauge connection pipe size _________________ inches

Discharge gauge elevation corr. ______________________ feet

MOTOR:** Rated HP ____________ Volts _______________ S.F. ___________

Barometric pressure ____________ inches Hg x 1.13 = __________ feet water

F.L. Amps ____________ F.L. Eff _____________ P.F. ___________

Liquid pumped ________________

S.G. __________

Phase _______________

Liquid temperature _____________ °F

Liquid vapor pressure ___________ psi x 2.31 = __________feet water

P

O

I

N
T

Discharge

Pressure

Gauge

Suction

Pressure

Gauge

Velocity

Head
(feet)

Total

Dynamic

Head

(TDH

2

)

FLOW

RPM

2

Moto

r

Volts

Motor Amps

Avg.

Amps

Pump

BHP

2

(calc’d)

Pump

Eff.

(calc’d)

Affinity Law

Corrections

Calc’d

N

P
S

H
A

N

P

S

H

R*

Read-

ing

Convert to
GPM

2

Leg

1

Leg

2

Leg

3

RPM

1

TDH

1

GPM

1

BHP

1

(PSI.)

(ft.)

(PSI.)

(ft.)

Disc.

Suct.

1

2

3

4

5

6

7

8

9

10

*

NPSHR taken from manufacturer’s pricebook curve.

Type of flow measurement device: ____________________________________

**

Motor information taken off motor nameplate.
See sheet 2 of 2 for useful formulas.

Readings taken by: ________________________________________________

Comments:

_______________________________________________________________

_______________________________________________________________

FIELD TEST REPORT

3409

IO

M
11/04

67

APPENDIX VII

7

Advertising