ENGINEERING DATA
Pump Size
10x14-20S
10x14-20L
12x16-23
14x16-17
14x18-23
14x18-28
CASING DATA
(All Dimensions in Inches)
125# FF Std.
Max. Suction Pressure (PSIG)
75
75
75
75
75
75
ASA Flanges
Max. Working Pressure (PSIG)
175
175
175
175
175
175
Max. Hydrostatic Test Pressure (PSIG)
262
262
262
262
262
262
Casing Material
Cast Iron
Cast Iron
Cast Iron
Cast Iron
Cast Iron
Cast
¬
250# FF
Max. Suction Pressure (PSIG)
200
200
200
200
200
200
®
ASA Flanges
Max. Working Pressure (PSIG)
300
300
300
300
300
300
Max. Hydrostatic Test Pressure (PSIG)
¯
450
450
450
450
450
450
Casing Material
Ductile Iron
Ductile Iron
Ductile Iron
Ductile Iron
Ductile Iron
Ductile Iron
Casing Wall Thickness
.625
.625
.625
.625
.625
.625
STUFFING BOX DATA
(All Dimensions in Inches)
Bore
5.125
5.125
5.125
5.125
5.875
5.875
Depth
4.812
4.812
4.812
4.812
4.812
4.812
Seal Cage Width
.75
.75
.75
.75
.75
.75
Packing No. Rings/Size Sq.
6/.625
6/.625
6/.625
6/.625
6/.625
6/.625
Shaft Sleeve O.D.
3.875
3.875
3.875
3.875
4.625
4.625
Mechanical Seal Size (Type 8-1)
3.875
3.875
3.875
3.875
4.625
4.625
Å
{
Mechanical Seal
{
Major Dia.
4.125
4.125
4.125
4.125
4.750
4.750
Size (Type 8-1B)
Minor Dia.
3.875
3.875
3.875
3.875
4.500
4.500
IMPELLER DESIGN DATA
(All Dimensions in Inches)
Number of Vanes
6
6
6
6
6
6
Inlet Area (Sq. Inches)
112
128
150
171
212
196
Inlet Velocity per 100 GPM (Ft/Sec)
.29
.25
.21
.19
.15
.16
Maximum Diameter
19.8
19.8
23.0
17.5
23.0
27.9
Minimum Diameter
9.4
14.0
13.0
12.5
14.0
14.0
Maximum Sphere
1.63
1.56
1.63
1.20
2.10
1.30
WR^2 for Maximum Diameter (Lbs-Ft^2)
47
52
109
46
120
254
Wear Ring Clearance — Dia. BRZ Impellers
.016-.019
.016-.019
.016-.019
.016-.019
.016-.019
.016-.019
Wear Ring Clearance — Dia. Cl and SS Impellers
.025-.028
.025-.028
.025-.028
.025-.028
.025-.028
.025-.028
SHAFT AND BEARING DATA
(All Dimensions in Inches)
At Coupling
3.125
3.125
3.125
3.125
3.125
3.125
Thru Impeller and Sleeves
3.311
3.311
3.311
3.311
4.061
4.061
Shaft Span
Bearing to Bearing Centerline
40.500
40.500
40.500
40.500
41.375
41.375
Ball Bearing
Inboard
6316
6316
6316
6316
6316
6316
Outboard
21316
21316
21316
21316
21316
21316
Frame Group
M
M
M
M
L
L
¬
With 250# FF flanges refer to pump as H6x10-22.
Flange dimensions are in accordance with ANSI A21.10,
AWWA C110 and ANSI B16.1 Class125.
®
Flange dimensions are in accordance with ANSI B16.1 Class
250 except flanges are flat faced.
¯
The hydrostatic test will be in accordance with the latest
edition of the Hydraulic Institute Standards, test will be
maintained for a minimum of 10 minutes.
°
6x10-22, 8x12-21, and 8x12-22M/L are standard with 125# FF
suction and 250# FF discharge flanges.
±
Balanced mechanical seals have a major and a minor