Engineering data, Casing data, Stuffing box data – Goulds Pumps 3409 - IOM User Manual

Page 60: Impeller design data, Shaft and bearing data

Advertising
background image

60

3409 IOM 11/04

ENGINEERING DATA

Pump Size

10x14-20S

10x14-20L

12x16-23

14x16-17

14x18-23

14x18-28

CASING DATA

(All Dimensions in Inches)

­

125# FF Std.

Max. Suction Pressure (PSIG)

75

75

75

75

75

75

ASA Flanges

Max. Working Pressure (PSIG)

175

175

175

175

175

175

Max. Hydrostatic Test Pressure (PSIG)

262

262

262

262

262

262

Casing Material

Cast Iron

Cast Iron

Cast Iron

Cast Iron

Cast Iron

Cast

¬

250# FF

Max. Suction Pressure (PSIG)

200

200

200

200

200

200

®

ASA Flanges

Max. Working Pressure (PSIG)

300

300

300

300

300

300

Max. Hydrostatic Test Pressure (PSIG)

¯

450

450

450

450

450

450

Casing Material

Ductile Iron

Ductile Iron

Ductile Iron

Ductile Iron

Ductile Iron

Ductile Iron

Casing Wall Thickness

.625

.625

.625

.625

.625

.625

STUFFING BOX DATA

(All Dimensions in Inches)

Bore

5.125

5.125

5.125

5.125

5.875

5.875

Depth

4.812

4.812

4.812

4.812

4.812

4.812

Seal Cage Width

.75

.75

.75

.75

.75

.75

Packing No. Rings/Size Sq.

6/.625

6/.625

6/.625

6/.625

6/.625

6/.625

Shaft Sleeve O.D.

3.875

3.875

3.875

3.875

4.625

4.625

Mechanical Seal Size (Type 8-1)

3.875

3.875

3.875

3.875

4.625

4.625

Å

{

Mechanical Seal

{

Major Dia.

4.125

4.125

4.125

4.125

4.750

4.750

Size (Type 8-1B)

Minor Dia.

3.875

3.875

3.875

3.875

4.500

4.500

IMPELLER DESIGN DATA

(All Dimensions in Inches)

Number of Vanes

6

6

6

6

6

6

Inlet Area (Sq. Inches)

112

128

150

171

212

196

Inlet Velocity per 100 GPM (Ft/Sec)

.29

.25

.21

.19

.15

.16

Maximum Diameter

19.8

19.8

23.0

17.5

23.0

27.9

Minimum Diameter

9.4

14.0

13.0

12.5

14.0

14.0

Maximum Sphere

1.63

1.56

1.63

1.20

2.10

1.30

WR^2 for Maximum Diameter (Lbs-Ft^2)

47

52

109

46

120

254

Wear Ring Clearance — Dia. BRZ Impellers

.016-.019

.016-.019

.016-.019

.016-.019

.016-.019

.016-.019

Wear Ring Clearance — Dia. Cl and SS Impellers

.025-.028

.025-.028

.025-.028

.025-.028

.025-.028

.025-.028

SHAFT AND BEARING DATA

(All Dimensions in Inches)

At Coupling

3.125

3.125

3.125

3.125

3.125

3.125

Thru Impeller and Sleeves

3.311

3.311

3.311

3.311

4.061

4.061

Shaft Span

Bearing to Bearing Centerline

40.500

40.500

40.500

40.500

41.375

41.375

Ball Bearing

Inboard

6316

6316

6316

6316

6316

6316

Outboard

21316

21316

21316

21316

21316

21316

Frame Group

M

M

M

M

L

L

¬

With 250# FF flanges refer to pump as H6x10-22.

­

Flange dimensions are in accordance with ANSI A21.10,
AWWA C110 and ANSI B16.1 Class125.

®

Flange dimensions are in accordance with ANSI B16.1 Class
250 except flanges are flat faced.

¯

The hydrostatic test will be in accordance with the latest
edition of the Hydraulic Institute Standards, test will be
maintained for a minimum of 10 minutes.

°

6x10-22, 8x12-21, and 8x12-22M/L are standard with 125# FF
suction and 250# FF discharge flanges.

±

Balanced mechanical seals have a major and a minor
diameter as listed.

Advertising