Suction-piping checklist – Goulds Pumps 3620 - IOM User Manual

Page 30

Advertising
background image

Installation

Check

Explanation/comment

Checked

Use cushioning devices.

This protects the pump from surges and water hammer
if quick-closing valves are installed in the system.

Alignment criteria for pump flanges

Type

Criteria

Axial

The flange gasket thickness is ±0.03 in. (0.8 mm).

Parallel

Align the flange to be within 0.001 in./in. to 0.03 in./
in. maximum (0.025 mm/mm to 0.8 mm/mm) of the
flange diameter.

Concentric

You can easily install the flange bolts by hand.

Fastening

WARNING:

• Only use fasteners of the proper size and material.
• Replace all corroded fasteners.
• Make sure that all fasteners are properly tightened and that there are no missing fasteners.

Suction-piping checklist

Performance curve reference

CAUTION:
Vary the capacity with the regulating valve in the discharge line. Never throttle the flow from the suction
side. This action can result in decreased performance, unexpected heat generation, and equipment
damage.

Net positive suction head available (NPSH

A

) must always exceed NPSH required (NPSH

R

) as

shown on the published performance curve of the pump.

Suction-piping checks

Check

Explanation/comment

Checked

Check that the distance between

This minimizes the risk of cavita-

the inlet flange of the pump and

tion in the suction inlet of the

the closest elbow is at least five

pump due to turbulence.

pipe diameters.
Check that elbows in general do

not have sharp bends.
Check that the suction piping is

The suction piping must never

one or two sizes larger than the

have a smaller diameter than the

suction inlet of the pump.

suction inlet of the pump.

Install an eccentric reducer be-
tween the pump inlet and the
suction piping.
Check that the eccentric reducer

at the suction flange of the pump
has the following properties:
• Sloping side down
• Horizontal side at the top
When suction strainers or suction Suction strainers help to prevent
bells are used, check that they are clogging.
at least three times the area of the Mesh holes with a minimum diam-

suction piping.

eter of 1/16 in. (1.6 mm) are
recommended.

If more than one pump operates

This recommendation helps you to

from the same liquid source,

achieve a higher pump perfor-

check that separate suction-piping mance.
lines are used for each pump.

28

Model 3620, API Type BB2 Single Stage / ISO 13709 1st/2nd Ed. / API 610 8th-11th Ed. Installation, Operation, and

Maintenance Manual

Advertising