Replace the wear parts, Replace the throat bushing – Goulds Pumps 3620 - IOM User Manual

Page 71

Advertising
background image

Maintenance

Pump size

Radial bearing Thrust bearing Bearing

Shaft turn

group

housing bore

M, MX

6312

7312/BECBM

5.1181

2.3628

5.1191

2.3623

L, LX

6313

7313/BECBM

5.5118

2.5597

5.5128

2.5592

XL

6318

7318/BECBM

7.4809

3.5440

7.4820

3.5434

X, XXL, XLX

6320

7320/BECBM

8.4652

3.9377

8.4663

3.9371

XX

6224

7320/BECBM

8.4652

Thrust

Radial

8.4663

3.9377

4.7255

3.9371

7.7249

Bearing housings

Perform these checks when you inspect the bearing housings:

• Check that the bearing housings are very clean, with no burrs.

• Remove all loose and foreign material.

• Check the bearing housing bores against the values in the Ball bearing fits table.

• Repair or replace housings as necessary.

Replace the wear parts

Replace the throat bushing

The throat bushing (125) is held in place by a press fit and tack welds.
1. Remove the bushing:

a) Grind out the tack weld.
b) Press the bushing (125) into the seal chamber of the case (100) and head (184) bore.

2. Install the bushing:

a) Thoroughly clean the bushing fit in the seal chamber of the case (100) and head (184).

Model 3620, API Type BB2 Single Stage / ISO 13709 1st/2nd Ed. / API 610 8th-11th Ed. Installation, Operation, and

69

Maintenance Manual

Advertising