Replace the wear rings – Goulds Pumps 3620 - IOM User Manual

Page 72

Advertising
background image

Maintenance

b) Chill the new bushing (125) using dry ice or other suitable chilling substance, and install

the bushing into the fit of the case (100) and head (184).
Be prepared to tap the bushing in place with a hardwood block or soft-faced hammer.

WARNING:
Dry ice and other chilling substances can cause physical injury. Contact the supplier for information and
advice for proper handling precautions and procedures.

c) Tack weld the bushing in place at three equidistant places.

Replace the wear rings

The casing and head wear rings (164) and impeller wear rings (142) are held in place by a
press fit and three setscrews (320).
1. Remove the wear rings:

a) Remove the setscrews.
b) Remove the wear rings from the casing (100), the impeller (101), and the head (184).

Use suitable pry or puller tools to force the rings from the fits.
You can also machine the rings for removal.

CAUTION:
Excessive machining can damage ring fits and render parts unusable.

2. Install the wear rings:

a) Thoroughly clean the wear-ring seats, and make sure that they are smooth and free of

scratches.

b) Heat the new impeller wear rings to 180°F–200°F (132°C–143°C) using a uniform

method for heating, such as an oven, and place them on the impeller (101) wear-ring
seats.

WARNING:
Wear insulated gloves when you handle rings. Rings will be hot and can cause physical injury.

70

Model 3620, API Type BB2 Single Stage / ISO 13709 1st/2nd Ed. / API 610 8th-11th Ed. Installation, Operation, and

Maintenance Manual

Advertising