SHUTDOWN

1.

Slowly close discharge valve.

2.

Shut down and lock driver to prevent accidental
rotation.

s

!

WARNING

When handling hazardous and/or toxic fluids, proper
personal protective equipment should be worn. If
pump is being drained, precautions must be taken to
prevent physical injury. Pumpage must be handled
and disposed of in conformance with applicable
environmental regulations.

FINAL ALIGNMENT

!

Alignment procedures must be followed to prevent
unintended contact of rotating parts. Follow
coupling manufacturer's coupling installation and
operation procedures.

1.

Run the unit under actual operating conditions for a
sufficient length of time to bring the pump and driver
and associated system up to operating temperature.

2.

Remove coupling guard. Refer to coupling guard
installation and disassembly instructions in Appendix
II
.

3.

Check alignment while unit is still hot per alignment
procedure in the Installation Section.

4.

Reinstall coupling guard.

26

3996 IOM 9/2010