Engineering data construction details power end – Goulds Pumps 3996 - IOM User Manual

Page 42

Advertising
background image

e.

Compress rotary portion of seal to correct
dimension as shown on seal manufacturer’s
drawing and tighten set screws.

f.

Remove visegrip and refer to Step 9 for further
instructions.

ENGINEERING DATA CONSTRUCTION DETAILS

Power End

38

3996 IOM 9/2010

POWER END

MODEL 3996 ST

MODEL 3996 MT

Shaft

Diameters

At Impeller

3/4" (19)

1" (25)

In Stuffing Box (Less Sleeve)

1 3/8" (35)

1 3/4" (44)

In Stuffing Box (With Sleeve)

1 1/8" (29)

1 1/1" (38)

Sleeve Outside Diameter

1 3/8" (35)

1 3/4" (44)

Between Bearings

1 1/2" (38)

2 1/8" (54)

At Coupling

7/8" (22)

1 1/8" (29)

Bearings

Radial

207-SF

309-SF

Coupling End (Double Row)

5306-KF

5309F

Bearing Span

4 1/8" (105)

6 3/4" (171)

Shaft Overhang

6 1/8" (156)

8 3/8" (213)

Stuffing

Box

Bore

2" (51)

2 1/2" (64)

Depth

2 1/8" (54)

2 5/8" (67)

Packing Size

5/16" x 5/16" (8 x 8)

3/8" x 3/8" (10 x 10)

No. of Rings

5

5

Width of Lantern Ring

7/16" (11)

5/8" (16)

Distance - End of Box to
Nearest Obstruction

2 3/16" (55)

3" (76)