Pump end – Goulds Pumps 3996 - IOM User Manual

Page 43

Advertising
background image

3996 IOM 9/2010

39

Pump End

Pump End

11

/2x2

-6

11

/2x3

-6

2x3

-6

11

/2x2

-8

11

/2x3

-8

11

/2x2

-1

0

11

/2x3

-1

0

2x3

-1

0

3x4

-1

0

11

/2x3

-1

3

2x3

-1

3

3x4

-1

3

4x6

-1

3

Maximum Diameter
Solids

11/32" 7/13" 3/8" 11/32" 7/16"

7/16"

7/32"

3/8"

5/8"

7/32"

3/8"

5/8"

1"

8.7

11.1

9.5

8.7

11.1

11.1

5.6

9.5

15.9

5.6

9.5

15.9

25

Shaft
Deflection

3500 RPM

3

6.2

7

6

7.8

7.2

8.6

9.8

15

10

15.7

35.5

-

Load Factor
(M)

1750 RPM

0.8

1.6

1.8

1.5

2.0

1.9

2.2

2.5

4.1

2.6

4.6

11.5

16.5

1150 RPM

0.3

0.7

0.8

0.7

0.9

0.8

1

1.1

1.7

1.2

1.9

5

6.8

Minimum Casing
Thickness

3/8" (9.5)

1/2" (12.7)

9/16" (14.3)

5/8" (15.9)

Casing Corrosion
Allowance

1/8" (3)

1/8" (3)

Working Pressure

See PT Charts in Figs. 17 and 18 on Pg. 43

Test Pressure

150% of Working Pressure at 100°F (38°C)

Maximum Liquid
Temp. (without
Cooling)

250°F (120°C)

Max Liquid Temp.
(with Cooling and
Grease Lube)

350°F (175°C)

Max. Liquid Temp.
(with Cooling and
Oil Mist)

500°F (260°C)

Unit Weight

SEE DIMENSIONS

3996ST

3996MT

6

Advertising