Troubleshooting, Causes and corrective measures, Problem possible causes and corrections – Goulds Pumps 3996 - IOM User Manual

Page 49: Cause remedy

Advertising
background image

TROUBLESHOOTING

TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

Causes and Corrective Measures . . . . . . . . . . . . . . . . . . . . . . . . . . 45

TROUBLESHOOTING

CAUSES AND CORRECTIVE MEASURES

3996 IOM 9/2010

45

Problem

Possible Causes and Corrections

A. No liquid delivered, not enough liquid delivered, or not

enough pressure.

1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 18, 19, 20.

B. Pump works a while and then quits.

4, 5, 7, 8, 9, 11, 12, 20.

C. Pump takes too much power.

6, 13, 14, 15, 16, 21, 22, 23, 24, 31.

D. Pump is noisy or vibrates.

15, 16, 17, 28, 31.

E. Pump leaks excessively at stuffing box

8, 24, 25, 26, 27.

F. High bearing temperature

15, 16, 17, 29, 30, 31.

G. Stuffing box overheating

8, 24, 25, 26, 27.

Cause

Remedy

1

Pump not primed or properly vented.

Check that casing and suction pipe are completely filled
with liquid.

2

Speed too low.

Check whether motor wiring is correct and receives full
voltage or turbine receives full steam pressure.

3

System discharge head too high.

Check system head (particularly friction losses).

4

Suction lift too high.

Check NPSH available (suction piping too narrow or long
may cause excessive friction losses). Check with vacuum
or compound gauge.

5

Impeller or piping obstructed.

Check for obstructions.

6

Wrong direction of rotation.

Check rotation.

7

Air pocket or leak in suction line.

Check suction piping for air pockets and/or air leaks.

8

Stuffing box packing or seal worn allowing leakage of air
into pump casing.

Check packing or seal and replace as required. Check for
proper lubrication.

9

Not enough suction head for hot or volatile liquids.

Increase suction head, consult factory.

10 Foot valve too small.

Install correct size foot valve.

11 Foot valve or suction pipe not immersed deep enough.

Consult factory for proper depth. Use baffle to eliminate
vortices.

12 Entrained air or gases in liquid.

Consult factory.

7