Alignment troubleshooting, Table 2 – Goulds Pumps ANSI FAMILY IOM (ATEX Compliant) User Manual

Page 34

Advertising
background image

ALIGNMENT TROUBLESHOOTING

32

ANSIFAM IOM - 5/08

Table 1

Cold Setting of Parallel Vertical Alignment

Pumpage

Temperature

Set Driver Shaft, Inches (mm)

3196

CV 3196

HT 3196

LF 3196

NM 3196

3198

3796

50° F (10° C)

.002 (.05) low

.002 (.05) low

0.000

.002 (.05) low

.002 (.05) low

.002 (.05) low

.002 (.05) low

150° F F (65° C)

.001 (.03) high

.001(.03) high

0.000

.001(.03) high

.001(.03) high

.001(.03) high

.001(.03) high

250° F (120° C)

.005 (.12) high

.005 (.12) high

0.000

.005 (.12) high

.005 (.12) high

.005 (.12) high

.005 (.12) high

350° F (175° C)

.009 (.23) high

.009 (.23) high

0.000

.009 (.23) high

N/A

.009 (.23) high

.009 (.23) high

450° F (218° C)

.013 (.33) high

.013 (.33) high

0.000

.013 (.33) high

N/A

N/A

.013 (.33) high

550° F (228° C)

.017 (.43) high

.017 (.43) high

0.000

.017 (.43) high

N/A

N/A

.017 (.43) high

650° F (343° C)

.021 (.53) high

.021 (.53) high

0.000

.021 (.53) high

N/A

N/A

N/A

700° F (371° C)

.023 (.58) high

.023 (.58) high

0.000

.023 (.58) high

N/A

N/A

N/A

NOTE: For the HT 3196, the cold setting of parallel vertical is 0.0 for all pumpage temperatures due to centerline mounting.

Table 2

Problem

Problem Cause

Remedy

Cannot obtain horizontal (Side-to-Side)
alignment, angular or parallel

Driver feet bolt bound.

Loosen pump hold down bolts and slide pump
and driver until horizontal alignment is
achieved.

Baseplate not leveled properly, probably
twisted.

Determine which corner(s) of the baseplate are
high or low and remove or add shims at the
appropriate corner(s) and realign.