Caution, Couple pump and driver, Warning – Goulds Pumps ANSI FAMILY IOM (ATEX Compliant) User Manual

Page 40: Table 3 impeller clearances, Table 3, cont’d impeller clearances

Advertising
background image

If using a cartridge mechanical seal, the centering
clips must be installed and set screws loosened prior
to setting impeller clearance.

l

!

!

CAUTION

Failure to do so could result in sparks, heat
generation, and mechanical seal damage.

Once proper impeller setting is achieved, tighten the
set screws in the seal locking ring and remove the
centering clips prior to starting the pump.

COUPLE PUMP AND DRIVER

s

!

WARNING

Lock out driver power to prevent accidental
rotation and physical injury.

The coupling used in an ATEX classified
environment must be properly certified.

1.

Install and lubricate coupling per manufacturer’s
instructions.

38

ANSIFAM IOM - 5/08

Service temperature in an ATEX classified environment is limited by Table 1 in the SAFETY section.

Table 3

Impeller Clearances

Cold Temperature Clearances for Various Service Temperatures, inches (mm)

Service Temperature

3196 and HT3196

LF3196

STX

MTX/LTX

XLTX/X17

STX MTX/LTX

inches

mm

inches

mm

inches

mm

inches

mm

-20 to 150°F (-29 to 66°C)

0.005

0.13

0.008

0.20

0.015

0.38

0.015

0.38

Up to 175°F (79°C)

0.005

0.13

0.008

0.20

0.015

0.38

0.015

0.38

Up to 200°F (93°C)

0.005

0.13

0.008

0.20

0.015

0.38

0.015

0.38

Up to 250°F (121°C)

0.006

0.16

0.009

0.23

0.016

0.41

0.016

0.41

Up to 300°F (149°C)

0.007

0.19

0.010

0.26

0.017

0.44

0.017

0.44

Up to 350°F (177°C)

0.009

0.22

0.012

0.29

0.019

0.47

0.019

0.47

Up to 400°F (204°C)

0.010

0.25

0.013

0.32

0.020

0.50

0.020

0.50

Up to 450°F (232°C)

0.011

0.28

0.014

0.35

0.021

0.53

0.021

0.53

Up to 500°F (260°C)

0.012

0.30

0.015

0.38

0.022

0.56

0.022

0.56

Up to 550°F (288°C)

0.013

0.33

0.016

0.41

0.023

0.59

0.023

0.59

Up to 600°F (316°C)

0.014

0.36

0.017

0.44

0.024

0.62

0.024

0.62

Up to 650°F (343°C)

0.016

0.39

0.019

0.47

0.026

0.65

0.026

0.65

Up to 700°F (371°C)

0.017

0.42

0.020

0.50

0.027

0.68

0.027

0.68

Table 3, cont’d

Impeller Clearances

Cold Temperature Clearances for Various Service Temperatures, inches (mm)

Service Temperature

CV 3196

1

3796

NM 3196

3198

STX MTX/LTX XLTX

STX MTX/LTX

STX

MTX/LTX

STX MTX/LTX

-20 to 150°F (-29 to 66°C)

0.06

1.52

0.015

0.38

0.005

0.13

0.008

0.20

0.015

0.38

Up to 175°F (79°C)

0.06

1.52

0.015

0.38

0.005

0.13

0.008

0.20

0.020

0.51

Up to 200°F (93°C)

0.06

1.52

0.015

0.38

0.005

0.13

0.008

0.20

0.024

0.61

Up to 250°F (121°C)

0.06

1.52

0.016

0.41

0.032

0.81

Up to 300°F (149°C)

0.06

1.52

0.017

0.44

0.040

1.02

Up to 350°F (177°C)

0.06

1.52

0.019

0.47

Up to 400°F (204°C)

0.06

1.52

0.020

0.50

Up to 450°F (232°C)

0.021

0.53

Up to 500°F (260°C)

0.022

0.56

Up to 550°F (288°C)
Up to 600°F (316°C)
Up to 650°F (343°C)
Up to 700°F (371°C)

Out of pump temperature range =

1

Clearance is set from the back of the impeller to the stuffing box cover / seal chamber / backplate.

Footnote #1: CV3196 impeller clearance is set off seal chamber face.