Table 3

Impeller Clearances

Cold Temperature Clearances for Various Service Temperatures, inches (mm)

Service Temperature

3196 and HT3196

LF3196

STX

MTX/LTX

XLTX/X17

STX MTX/LTX

inches

mm

inches

mm

inches

mm

inches

mm

-20 to 150°F (-29 to 66°C)

0.005

0.13

0.008

0.20

0.015

0.38

0.015

0.38

Up to 175°F (79°C)

0.005

0.13

0.008

0.20

0.015

0.38

0.015

0.38

Up to 200°F (93°C)

0.005

0.13

0.008

0.20

0.015

0.38

0.015

0.38

Up to 250°F (121°C)

0.006

0.16

0.009

0.23

0.016

0.41

0.016

0.41

Up to 300°F (149°C)

0.007

0.19

0.010

0.26

0.017

0.44

0.017

0.44

Up to 350°F (177°C)

0.009

0.22

0.012

0.29

0.019

0.47

0.019

0.47

Up to 400°F (204°C)

0.010

0.25

0.013

0.32

0.020

0.50

0.020

0.50

Up to 450°F (232°C)

0.011

0.28

0.014

0.35

0.021

0.53

0.021

0.53

Up to 500°F (260°C)

0.012

0.30

0.015

0.38

0.022

0.56

0.022

0.56

Up to 550°F (288°C)

0.013

0.33

0.016

0.41

0.023

0.59

0.023

0.59

Up to 600°F (316°C)

0.014

0.36

0.017

0.44

0.024

0.62

0.024

0.62

Up to 650°F (343°C)

0.016

0.39

0.019

0.47

0.026

0.65

0.026

0.65

Up to 700°F (371°C)

0.017

0.42

0.020

0.50

0.027

0.68

0.027

0.68

Table 3, cont’d

Impeller Clearances

Cold Temperature Clearances for Various Service Temperatures, inches (mm)

Service Temperature

CV 3196

1

3796

NM 3196

3198

STX MTX/LTX XLTX

STX MTX/LTX

STX

MTX/LTX

STX MTX/LTX

-20 to 150°F (-29 to 66°C)

0.06

1.52

0.015

0.38

0.005

0.13

0.008

0.20

0.015

0.38

Up to 175°F (79°C)

0.06

1.52

0.015

0.38

0.005

0.13

0.008

0.20

0.020

0.51

Up to 200°F (93°C)

0.06

1.52

0.015

0.38

0.005

0.13

0.008

0.20

0.024

0.61

Up to 250°F (121°C)

0.06

1.52

0.016

0.41

0.032

0.81

Up to 300°F (149°C)

0.06

1.52

0.017

0.44

0.040

1.02

Up to 350°F (177°C)

0.06

1.52

0.019

0.47

Up to 400°F (204°C)

0.06

1.52

0.020

0.50

Up to 450°F (232°C)

0.021

0.53

Up to 500°F (260°C)

0.022

0.56

Up to 550°F (288°C)
Up to 600°F (316°C)
Up to 650°F (343°C)
Up to 700°F (371°C)

Out of pump temperature range =

1

Clearance is set from the back of the impeller to the stuffing box cover / seal chamber / backplate.