4.

Check frame face run out. Rotate shaft so
indicator rides along the fit for 360 degrees. If total
indicator reading is greater than 0.001 in. (.025 mm)
disassemble and determine cause (Fig. 141).

5.

Place manila gasket (360D) on frame (228)
(Fig. 142).

NOTE: The gasket is designed to fit one way
only. The dowel pins (469B) may be started in
their holes to hold the gasket in place.

6.

Install frame adapter (108), onto frame assembly.
Align bolt holes and dowel locations with those on
frame (Fig. 142).

7.

Install dowel pins (469B) and bolts (370B).
Tighten bolts to

Table 9 torque specifications in a

crisscross pattern.

8.

Check adapter fits. Rotate shaft through 360
degrees. If total indicator reading is greater than
.005 in. (.13 mm), determine the cause and
correct before proceeding (Fig. 143).

9.

Install inboard labyrinth oil seal (333A) into
adapter (108) / bearing frame (228). It is an
O-ring fit. Position the labyrinth seal drain slots at
the bottom (6 o’clock) position. (Fig. 144).

NOTE: For detailed labyrinth seal installation
instructions, see Appendix IV or VIII, Labyrinth
Seal Installation Instructions.

ANSIFAM IOM - 5/08

85

6

Fig. 141

Fig. 142

Fig. 143

Fig. 144