General precautions – Goulds Pumps ANSI FAMILY IOM (ATEX Compliant) User Manual

Page 5

Advertising
background image

S-5

General Precautions

WARNING

Before beginning any alignment procedure, make sure driver power is locked out.
Failure to lock out driver power will result in serious physical injury.

CAUTION

Piping:
Never draw piping into place by forcing at the flanged connections of the pump.
This may impose dangerous strains on the unit and cause misalignment between
pump and driver. Pipe strain will adversely effect the operation of the pump
resulting in physical injury and damage to the equipment.

WARNING

Flanged Connections:
Use only fasteners of the proper size and material.

WARNING

Replace all corroded fasteners.

WARNING

Ensure all fasteners are properly tightened and there are no missing fasteners.

WARNING

Startup and Operation:
When installing in a potentially explosive environment, please ensure that the
motor is properly certified.

WARNING

Operating pump in reverse rotation may result in contact of metal parts, heat
generation, and breach of containment.

WARNING

Lock out driver power to prevent accidental start-up and physical injury.

WARNING

The impeller clearance setting procedure must be followed. Improperly setting
the clearance or not following any of the proper procedures can result in sparks,
unexpected heat generation and equipment damage.

WARNING

If using a cartridge mechanical seal, the centering clips must be installed and set
screws loosened prior to setting impeller clearance. Failure to do so could result
in sparks, heat generation, and mechanical seal damage.

WARNING

The coupling used in an ATEX classified environment must be properly certified
and must be constructed from a non-sparking material.

WARNING

Never operate a pump without coupling guard properly installed. Personal injury
will occur if pump is run without coupling guard.

WARNING

Make sure to properly lubricate the bearings. Failure to do so may result in excess
heat generation, sparks, and / or premature failure.

CAUTION

The mechanical seal used in an ATEX classified environment must be properly
certified. Prior to start up, ensure all points of potential leakage of process fluid to
the work environment are closed.

CAUTION

Never operate the pump without liquid supplied to mechanical seal. Running a
mechanical seal dry, even for a few seconds, can cause seal damage and must be
avoided. Physical injury can occur if mechanical seal fails.

WARNING

Never attempt to replace packing until the driver is properly locked out and the
coupling spacer is removed.

WARNING

Dynamic seals are not allowed in an ATEX classified environment.

WARNING

DO NOT operate pump below minimum rated flows or with suction and/or
discharge valve closed. These conditions may create an explosive hazard due to
vaporization of pumpage and can quickly lead to pump failure and physical injury.

Advertising