General precautions – Goulds Pumps ANSI FAMILY IOM (ATEX Compliant) User Manual

Page 4

Advertising
background image

S-4

GENERAL PRECAUTIONS

WARNING

A pump is a pressure vessel with rotating parts that can be hazardous. Hazardous fluids may be contained by the
pump including high temperature, flammable, acidic, caustic, explosive, and other risks. Operators and
maintenance personnel must realize this and follow safety measures. Personal injuries will result if procedures
outlined in this manual are not followed. ITT Goulds Pumps will not accept responsibility for physical injury,
damage or delays caused by a failure to observe the instructions in this manual and the IOM provided with your
equipment.

General Precautions

WARNING

NEVER APPLY HEAT TO REMOVE IMPELLER. It may explode due to
trapped liquid.

WARNING

NEVER use heat to disassemble pump due to risk of explosion from tapped liquid.

WARNING

NEVER operate pump without coupling guard correctly installed.

WARNING

NEVER run pump below recommended minimum flow when dry, or without
prime.

WARNING

ALWAYS lock out power to the driver before performing pump maintenance.

WARNING

NEVER operate pump without safety devices installed.

WARNING

NEVER operate pump with discharge valve closed.

WARNING

NEVER operate pump with suction valve closed.

WARNING

DO NOT change service application without approval of an authorized ITT
Goulds Pumps representative.

WARNING

Safety Apparel:

ΠInsulated work gloves when handling hot bearings or using bearing heater
ΠHeavy work gloves when handling parts with sharp edges, especially

impellers

ΠSafety glasses (with side shields) for eye protection
ΠSteel-toed shoes for foot protection when handling parts, heavy tools, etc.
ΠOther personal protective equipment to protect against hazardous/toxic fluids

WARNING

Receiving:
Assembled pumping units and their components are heavy. Failure to properly lift
and support equipment can result in serious physical injury and/or equipment
damage. Lift equipment only at specifically identified lifting points or as
instructed in the current IOM. Current manuals are available at

www.gouldspumps.com/literature_ioms.html

or from your local ITT Goulds

Pumps sales representative. Note: Lifting devices (eyebolts, slings, spreaders, etc.)
must be rated, selected, and used for the entire load being lifted.

WARNING

Alignment:
Shaft alignment procedures must be followed to prevent catastrophic failure of
drive components or unintended contact of rotating parts. Follow coupling
manufacturer’s coupling installation and operation procedures.

Advertising