Atex considerations and intended use, Table 1 – Goulds Pumps ANSI FAMILY IOM (ATEX Compliant) User Manual

Page 7

Advertising
background image

S-7

ATEX CONSIDERATIONS and INTENDED USE

Special care must be taken in potentially explosive environments to ensure that the equipment is properly
maintained. This includes but is not limited to:

1. Monitoring the pump frame and liquid end temperature.
2. Maintaining

proper

bearing lubrication.

3. Ensuring that the pump is operated in the intended hydraulic range.

The ATEX conformance is only applicable when the pump unit is operated within its intended use. Operating,
installing or maintaining the pump unit in any way that is not covered in the Instruction, Operation, and
Maintenance manual (IOM) can cause serious personal injury or damage to the equipment. This includes any
modification to the equipment or use of parts not provided by ITT Goulds Pumps. If there is any question
regarding the intended use of the equipment, please contact an ITT Goulds representative before proceeding.
Current IOMs are available at

www.gouldspumps.com/literature_ioms.html

or from your local ITT Goulds

Pumps Sales representative.

All pumping unit (pump, seal, coupling, motor and pump accessories) certified for use in an ATEX classified
environment, are identified by an ATEX tag secured to the pump or the baseplate on which it is mounted. A
typical tag would look like this:

The CE and the Ex designate the ATEX compliance. The code directly below these symbols reads as follows:

II

= Group 2

2 =

Category

2

G/D

= Gas and Dust present

T4

= Temperature class, can be T1 to T6 (see Table 1)

Table 1

Code

Max permissible

surface temperature

o

F (

o

C)

Max permissible

liquid temperature

o

F (

o

C)

T1

842 (450)

700 (372)

T2

572 (300)

530 (277)

T3

392 (200)

350 (177)

T4

275 (135)

235 (113)

T5

212 (100)

Option not available

T6

185 (85)

Option not available

The code classification marked on the equipment must be in accordance with the specified area where the
equipment will be installed. If it is not, do not operate the equipment and contact your ITT Goulds Pumps sales
representative before proceeding.

Advertising