Fig. 6

3. Discard the condensate

water from the bucket.

Adapter A

Drain Hose Segment

Continuous Drain Plug

Drain Hose segment

attached to Adapter A

Fig. 10

Fig. 11

Fig. 8

Fig. 7

Reinstall pump

hose properly

Pump suction line

drops down

Fig. 12

Drain Hose

Connector

Fig. 13

Garden Hose

Female thread end

Owner’s Manual

BHD-H/ BHDP-H Portable Dehumidifier

Heat Controller

9

2. Condensate Drainage (gravity drainage)

• Water can be automatically emptied into a floor drain by attaching

the unit with a water hose, a standard garden hose to the

unit. The garden hose is not supplied with the unit, but can be

purchased separately from a local hardware store.

• Push the drain hose segment onto the hose barb Adapter A

(See Fig. 10).

NOTE: Some models may not require this step.

• Remove the continuous drain plug from the outlet on the back of

the unit. (See Fig. 11).

• Remove the bucket, then insert the continuous drain hose through

the continuous drain outlet of the unit so that the threaded end of

Adapter A is facing outward from the rear of the unit. While looking

into the empty cavity of the unit where the bracket normally

resides, pull the hose until you can securely slide it onto the

connector inside the cavity where the bucket resides. (See Fig.

12).

• Tighten the Adaptor A to the rear unit securely with two screws.

• Connect one end of the garden hose to the threaded end of

Adapter A (See Fig. 13). Run the other end of the garden hose to

the floor drain or a suitable drainage facility.

• Make sure the hose connections are secure, so there are no

leaks.

• Ensure that there are no kinks in the hose that will stop the water

flow.

• Ensure end of the hose is level or pointed downward to let the

water flow freely by gravity.

• Place the bucket back into the unit and make sure that it is seated

properly.

• Select the desired humidity setting and fan speed on the control

panel continuous draining to start.