OPERATING THE UNIT

Heat Controller

BHD-H/ BHDP-H Portable Dehumidifier

Owner’s Manual

3. Condensate Pump Drainage

Water can be automatically emptied into a floor drain or a suitable

drainage location by attaching the factory supplied pump drain hose

(0od=1/4”) to the pump drain outlet on the rear of the unit.

• Before activating the condensate pump, ensure that the garden hose,

continuous drain hose and Adapter A subassembly are removed from

the unit. Be certain that the continuous drainage outlet is plugged

securely. (See Fig. 14).

• Next insert the factory supplied pump condensate hose into the pump

discharge outlet. Ensure that the connection is secure to prevent water

leaks by slightly tugging on the hose gently. (See Fig. 15).

• Direct the opposite end of the pump’s drain hose toward the floor drain

or other suitable drainage location, ensuring that there are no kinks in

the hose to obstruct condensate drainage. Ensure that the end of the

hose is level or directed downward into the drain for proper drainage.

• Press the button labeled pump on the control panel, then select the

desired relative humidity level and fan speed to activate the pump.

When the bucket is full, the pump will begin to operate .

NOTE: The

pump may sound noisy when it starts to work for the first 3-5 minutes.

This is a normal phenomenon.

ATTENTION: If the pump operation light blinks when the pump is

operational, this means there is a problem with the pump feature that

requires trouble shooting. CHECK THE FOLLOWING:

• Ensure the pump’s strainer is not clogged. To check the strainer and/or

unclog it. Remove the bucket. Simply pull down the condensate pump’s

inlet hose. The strainer is a small screened cup, which can easily twist

off to be cleaned. Remove only debris from the screen of the strainer

and twist it back on the pump inlet hose. Push the pump inlet hose

back into the proper position and re-install the bucket. (See Fig. 16).

• Check that the pump’s drain hose is not kinked or has anything

blocking the condensate from draining.

• Turn on the unit. Ensure the bucket is empty, then re-install it. Be

certain it is properly seated.

• Turn off the unit, then turn on again. If the error repeats, call for service.

CAUTION:

• Do not use the pump feature when the outdoor temperature is equal

to or less than 32°F (0°C), otherwise condensate may freeze inside

the pump’s drain line, blocking condensate removal and possibility

damaging the pump. Make sure to empty the bucket once a week when

using the pump drainage feature.

• When the pump drainage feature is not being used, remove the

pump drain hose from the outlet by pushing the pump’s drain outlet

connection toward the cabinet while pulling the pump drain hose

outward, away from the cabinet. (See Fig. 17).

10

Fig. 14

Continuous Drain Plug

Fig. 15

Fig. 16

Fig. 17

Garden Hose,

continuous drain hose

segment and Adapter A

Pump Drain Outlet

Pump Drain Hose

Pump Inlet Hose

with Strainer

Push the connector

toward the cabinet

Pull the pump

drain hose away

from the cabinet

1

2

Advertising