Owner’s Manual

BHD-H/ BHDP-H Portable Dehumidifier

Heat Controller

5

Display

Shows the set % relative humidity level from 35% to

85% or the auto start/stop time (0~24 hours) as it is

being set. Also shows the actual room humidity level

in a range of 30% RH (Relative Humidity) to 90%RH

(Relative Humidity) with an accuracy of +5%.

Error Codes and Protective Features:

AS- Humidity sensor error--Unplug the unit and plug it

back in. If error repeats, call for service.

ES- Temperature sensor error-- Unplug the unit and

plug it back in. If error repeats, call for service.

P2- Bucket is full or bucket is not in right position--

Empty the bucket and replace it in the right position.

Eb- The bucket has been removed from the unit or

is not in the right position. Replace or reposition the

bucket properly.

EC- Unit malfunction--Ensures the unit is operating

within the design parameters for temperature. If this

error occurs, turn off the unit and turn on again to

reset. If this error occurs after powering off and back

on call for service.

OTHER FEATURES

8

Bucket Full Light

Illuminates when the bucket is ready to be emptied, or when

the bucket is removed or not seated in the proper position.

Auto Shut Off

The dehumidifier shuts off after 30 seconds when the

bucket is full, or when the bucket is removed or not

seated in the proper position. When the set humidity is

reached, the unit will shut off automatically. For some

models, the fan motor will continue operating.

Exception

Does not apply in continuous operation.

Auto Defrost

When frost builds up on the evaporator coils, the

compressor will cycle off and the fan will continue to run

until the frost disappears.

Wait 3 minutes before resuming operation

After the unit has stopped, it can not be restarted in the

first 3 minutes. This is to protect the unit. Operation will

automatically occur after 3 minutes.

Check filter feature

The system starts to count the time once the fan motor

operates. The check filter feature can be only activated

when the accumulated operation time achieves 250

hours or more. The Reset light(Clean filter indicator

light) flashes one time per second. After cleaning the air

filter, press the Filter pad to turn the filter light (clean filter

indicator light) off the time resets.

Turbo Light

Illuminates when the fan speed is set up to Turbo mode.

Normal Light

NOTE: Applies to models without built-in pump only.

Illuminates when the fan speed is set to normal, which is

low fan speed.

Continuous Light

NOTE: Applies to models with built-in pump only.

Illuminates when continuous operation is in effect.

Auto-Restart

If the unit turns off unexpectedly due to power outage,

it will restart with the previous function setting automa-

tically when the power resumes.

Setting the Timer

• When the unit is on, first press the Timer button, the

Timer Off indicator light illuminates. It indicates the

Auto Stop program is initiated. Press it again the Time

On indicator light illuminates. It indicates the Auto Start

is initiated.

• When the unit is off, first press the Timer button, the

TIMER ON indicator light illuminates. It indicates the

Auto Start program is initiated. Press it again the Time

Off indicator light illuminates. It indicates the Auto Stop

is initiated.

• Press or hold the UP or DOWN pad to change the Auto

time by 0.5 hour increments, up to 10 hours, then at 1

hour increments up to 24 hours. The control will count

down the time remaining until start.

• The selected time will register in 5 seconds and the

system will automatically revert back to display the

previous humidity setting.

• When the Auto start & Auto stop times are set,

within the same program sequence, TIMER ON OFF

indicator lights illuminate identifying both ON and OFF

times are now programmed.

• Turning the unit ON or OFF at any time or adjusting

the timer setting to 0.0 will cancel the Auto Start/Stop

function.

• When LED display window displays the code of P2,

the Auto Start/Stop function will also be cancelled.