Heat Controller

BHD-H/ BHDP-H Portable Dehumidifier

Owner’s Manual

4

CONTROL PANEL

BHDP Models with built-in pump:

BHD Models without built-in pump:

When you push the button to change operation modes,

the unit will make a beep sound to indicate it received the command.

Pump Operation (Models with built-in pump only)

Press to activate pump operation. (See. Fig. 1)

NOTE: Ensure the pump drain hose is installed

onto the unit, the continuous drain hose is removed and plug

is reinstalled before the pump operation is activated. When

the bucket is full,the pump starts to work. Do not use the

pump feature when the outdoor temperature is equal to or

less than (32°F) 0°C.

Continuous Dehumidifying Operation

For models with out built-in pump, continuous operation

is activated by pressing the CONT. button on the control

panel. (See. Fig. 1).This allows the dehumidifier to run

continuously at 35% RH (relative humidity) without cycling

the compressor and fan on and off when the desired

humidity set point is achieved. By continuously running

the fan and compressor, constant dehumidification occurs,

which achieves the maximum moisture removal from the air.

Filter

The check filter feature is a reminder to clean the Air Filter

for more efficient operation. The Filter light (clean filter light)

will illuminate after 250 hours of operation to remind you to

clean the filter. After cleaning the filter, press the Filter pad

and the light will go off.

Fan

Controls the fan speed. Press to select Turbo or Normal fan

speed. Set the fan control to Turbo for maximum moisture

removal. When the humidity has been reduced or quieter

operation is preferred, set the fan speed to Normal. For

models without pumps, the Turbo or Normal indicator lights

will display for the corresponding fan speed. For models

with built in pump, the Turbo indicator light will display when

Turbo fan speed is selected. The Turbo indicator light will

be off when the fan is in Normal mode. There is an audible

difference between Turbo and Normal speeds.

Power Pad

Press to turn the dehumidifier on and off

UP/DOWN BUTTONS

Humidity Set Point Control

The humidity level can be set within a range of 35%RH

(Relative Humidity) to 85%RH (Relative Humidity) in 5%

increments. For drier air, press the - pad and set to a lower

percent value(%). For damper air, press the + pad and set

a higher percent value(%)

TIMER Set Time

Use the Up/Down pads to set the Auto start and Auto stop

time from 0.0 to 24 hours. See Timer below.

Continuous Operation Light (See. Fig. 1)

To run the unit in continuous mode, press the button until

the display reads 35% RH. Then press the - button again

until the display reads CO for continuous operation. To

stop continuous operation, press the + button and set the

desired relative humidity level to resume nominal operation.

NOTE: See 1B for a description of the continuous operation

feature.

TIMER

Press to initiate the Auto start and Auto stop feature, in

conjunction with the + and - key pads to set the start are

stop time.

1B

1B

4

1A

2

3

8

5

6

7

1A

- +

Fig. 1

Fig. 2