Electrical - thermostat wiring, Ѥ caution! ѥ ѥ caution! ѥ – Comfort-Aire HTH Series User Manual

Page 23

Advertising
background image

23

Installation, Operation & Maintenance

HTV/HTD/HTH SERIES

Heat Controller, Inc.

Electrical - Thermostat Wiring

Figure 24: Units With Optional ECM Fan.

Figure 25: Typical Thermostat 2 Heat/1 Cool (PSC Fan)

Thermostat Installation

The thermostat should be located on an interior wall in a
larger room, away from supply duct drafts. DO NOT locate
the thermostat in areas subject to sunlight, drafts or on
external walls. The wire access hole behind the thermostat
may in certain cases need to be sealed to prevent erroneous
temperature measurement. Position the thermostat back
plate against the wall so that it appears level and so the
thermostat wires protrude through the middle of the back
plate. Mark the position of the back plate mounting holes
and drill holes with a 3/16” (5mm) bit. Install supplied
anchors and secure plate to the wall. Thermostat wire must
be 18 AWG wire. Wire the appropriate thermostat as shown
in Figures 24 and 25 to the low voltage terminal strip on the
CXM (units with PSC motor) or ECM control board (units
with ECM motor). Practically any heat pump thermostat will
work with these units, provided it has the correct number of
heating and cooling stages.

ATP32U04 Thermostat

Connection to ECM Control

Compressor

Compressor Stage 2

Reversing Valve

Fan

24Vac Hot

24Vac Common

Fault LED

ECM

Board

Y1
Y2

W

DH

O
G
R
C

AL1

Y1
Y2

W

DH

O
G
R
C

L

Dehumidification

Units with CXM or DXM board and ECM fan motor, utilizing ECM dehumidification
mode (without ClimaDry option)

Notes:
1) Units with whole house dehumidification option have slightly different

thermostat wiring.Terminal DH at the thermostat is connected to terminal H at
the DXM board

2) ECM dehumidification mode slows down fan speed in the cooling mode when

dehumidification output from thermostat is active. Normal heating and cooling fan
speeds are not affected.

3) ECM board DIP switch SW9 must be in dehumid. mode for

ECM dehumidification mode.

Auxiliary Heat

ATM21U01 Thermostat

Connection to CXM Control

Compressor

Heating Stage 2

Reversing Valve

Fan

24Vac Hot

24Vac Common

Fault LED

Y

Y2/W

O
G
R
C

L

Y

W

O
G
R
C

AL1

CXM

NOTICE:

Units with ClimaDry whole house dehumidiÄ cation

option require a separate humidistat or thermostat part
number ATP32U04 (See ClimaDry AOM for more details).

ѥ

CAUTION!

ѥ

ѥ

CAUTION!

ѥ

CAUTION!

Refrigerant pressure activated water regulating

valves should never be used with ClimateMaster
equipment.

CAUTION!

Many units are installed with a factory or

¿

eld

supplied manual or electric shut-off valve.

DAMAGE

WILL OCCUR

if shut-off valve is

closed

during unit

operation. A high pressure switch must be installed on
the heat pump side of any

¿

eld provided shut-off valves

and connected to the heat pump controls in series with
the built-in refrigerant circuit high pressure switch to
disable compressor operation if water pressure exceeds
pressure switch setting. The

¿

eld installed high pressure

switch shall have a cut-out pressure of 300 psig and a
cut-in pressure of 250 psig. This pressure switch can
be ordered from ClimateMaster with a 1/4” internal

À

are

connection as part number 39B0005N02.

Manufacturer

Manufacturer

Units with CXM or DXM board and ECM fan motor, utilizing ECM dehumidifi cation mode

Notes:

1) ECM dehumidifi cation mode slows down fan speed in the cooling mode when

dehumidifi cation output from thermostat is active. Normal heating and cooling fan
speeds are not affected.

2) ECM board DIP switch SW9 must be in dehumid. mode for ECM dehumidifi cation mode.

Advertising